WenmarOpen by Wenmar Pro

Service bulletins for the 2017 Subaru Crosstrek

A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.

338 on file from NHTSA, as of 2026-10-19.

By type

By component

By trouble code

By topic

Only bulletins with component: Heating and air conditioning are shown. Show all

Bulletins, newest first
10-96-192020-01-07. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT:APPLIANCE:AIR CONDITIONER. This bulletin announces availability of a new HVAC blower motor unit assemblies developed to address isolated concerns of the blower motor becoming inoperative. If this issues occurs on models with Auto A/C, the blower fan may become totally inoperative. If this issue occurs on models with Manual A/C, the blower fan may operate on high speed only. The root cause of these conditions is water intrusion into the blower motor causing rust and corrosion to develop. Over time, the blower motor may begin to draw more electrical current to operate. if that occurs, the additional draw can cause the related fuse and/ or blower resistor to fail. To address this condition, additional packing has been added to improve sealing of the blower unit case along with development of a new style cabin air filter which also in corporates improved sealing.
15-222-182018-06-18. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; EQUIPMENT. This bulletin announces a design change to the A/C Condenser receiver-dryer assembly. The change involves the addition of a rubber end cap and retaining clip onto the bottom of the receiver-dryer tank portion to prevent corrosion intrusion and enhance sealing.
10-83-15R2018-04-02. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Models with Manual HVAC Systems only. This Service Information bulletin provides precautions to use when removing the HVAC control panel to prevent damaging the blower fan speed switch. When removing the control panel, if the fan speed switch wiring harness is pulled taught or becomes stressed, the switch may be damaged. If the connector (lower) portion of the switch becomes separated from the switch body even slightly (see Fig. 1 on page 2), the HVAC control panel assembly must be replaced. The switch itself is not serviceable. The related instrument panel (IP) wiring harness must also be inspected and replaced if any damage is confirmed. NOTE: For 2012MY Impreza, see TSB 10-78-12, dated 4/18/2012.

The summaries are NHTSA's. Each bulletin's page links NHTSA's copy of the manufacturer's document.