Bulletins, newest first
M6401082019-07-13. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; EQUIPMENT:ELECTRICAL. Air Conditioning System Leak Testing. The customer complains of poor or no air conditioning cooling. After further diagnosis, the system is found to be low or empty of a refrigerant charge, but when using an electronic leak detector, no leak can be found. CAUSE: In most cases, an electronic leak detector is not sufficient for identifying small leaks in the system. Electronic leak detectors can give false alarms and can lead to an improper diagnosis of small leaks. A leak cannot be located exactly if accessibility is impaired (in the case of the expansion valve, evaporator or condenser).
M0111162018-12-10. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; ELECTRICAL SYSTEM:SOFTWARE. ?OC3 SEAT OCCUPANCY MAT: LIMITED WARRANTY EXTENSION TO 10 YEARS/120,000 MILES. This Service Information bulletin supersedes SI 01 11 16 dated December 2016.
M6401142018-11-13. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Automatic Deactivation of Recirculation Mode. The customer states the recirculation display goes out, even though the recirculation button was switched on. CAUSE The automatic recirculation air deactivation feature was introduced in July 2012. Note: If the customer dislikes this feature, it can be deactivated by using the following steps.
M6401142018-11-13. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. Automatic Deactivation of Recirculation Mode. The customer states the recirculation display goes out, even though the recirculation button was switched on. CAUSE The automatic recirculation air deactivation feature was introduced in July 2012. Note: If the customer dislikes this feature, it can be deactivated by using the following steps.
M6402152018-11-13. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM:FAN/MOTOR; ENGINE AND ENGINE COOLING. The Blower Motor is Faulty. The blower motor does not operate at any fan speed. The blower motor may work intermittently with the blower fan speed operating only on FULL speed. CAUSE The blower motor is faulty and causes the blower resistor to fail.
M6402152018-11-05. Service bulletin. EQUIPMENT; EQUIPMENT:APPLIANCE:AIR CONDITIONER. This Service Information bulletin supersedes SI M64 02 15 dated August 2015. SUBJECT The Blower Motor is Faulty. The blower motor does not operate at any fan speed. The blower motor may work intermittently with the blower fan speed operating only on FULL speed. CAUSE The blower motor is faulty and causes the blower resistor to fail.
M6401142018-11-05. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Automatic Deactivation of Recirculation Mode. The customer states the recirculation display goes out, even though the recirculation button was switched on. CAUSE The automatic recirculation air deactivation feature was introduced in July 2012. Note: If the customer dislikes this feature, it can be deactivated by using the following steps.
SI M64-02-082008-09-10. Service bulletin. EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL; EQUIPMENT:APPLIANCE:AIR CONDITIONER. MINI: DRIVER FOOTWELL AREA BECOMES HOT. THE HEARTER CORE PIPES ARE POORLY INSULATED. MODEL R56. *PE

The summaries are NHTSA's. Each bulletin's page links NHTSA's copy of the manufacturer's document.