| LI27.00-P-073124 | 2024-07-31. Service bulletin. POWER TRAIN. Complaint Customer complaints relating to automatic transmission 725.0 (NAG3 Classic / 9G-TRONIC automatic transmission) and 725.1 (NAG3 facelift/9G-TRONIC automatic transmission facelift) For faster, more effective and more targeted diagnosis, Intelligent Predictive Repair (IPR) has been developed and integrated into XENTRY Diagnosis. This ensures an automated diagnosis process. Cause As part of the on-going quality monitoring process and associated quality and damaged part appraisals, a high number of ineffective repairs have been discovered. Such ineffective repairs have a negative impact on all those involved. For the customer, it means high costs and long repair times and for the dealer, it may result in the warranty claim being rejected. Remedy General note: IPR is available for: ·NAG3 Classic (automatic transmission 725.0) ·NAG3 - AMG sports models (AMG 43 and AMG 53 with converter) ·NAG3 - AMG 63 ·NAG3 - Hybrid |
|---|---|
| LI27.10-P-075869 | 2024-07-30. Service bulletin. POWER TRAIN. Complaint Only vehicles with a variable transfer case are affected. Can be identified through control unit N45 or N15/7 in the quick test When accelerating with light load, vibrations or jolting sensation may come from the drivetrain Cause Modified oil quality of the transfer case over time Remedy Check initial quick test for faults in the following control units N45 - All-wheel drive (ARS) N127 - 'Drivetrain' (PTCU) control unit Y3/8 - Transmission control for 9-gear transmission (VGS) N3/10 - Engine electronics for combustion engine If faults are present, process them as per the guided test in Xentry If no faults are present: Check the oil level of the transmission If the oil level is correct: Unplug the connector for the transfer cases control unit Reassess the vehicle on a subsequent test drive If the complaint no longer occurs: Perform an oil change of the transfer case Reassess the vehicle following the oil change If the problem continues to occur with the plug removed or after the oil change has been carried out: Create a TIPS case with the following data Initial quick test with fault freeze frame data EEPROM data from Y3/8 Transmission control unit EEPROM data from N45 All-wheel drive Injector performance data |
| LI27.60-P-077704 | 2024-07-04. Service bulletin. POWER TRAIN. Complaint DSI selection lever module cannot be switched to park position "P" - malfunction of "P" button Note: Vehicle can still be placed into park by opening driver's door, or turning off ignition. Please refer to operator's manual section, "Engaging park position P," for additional instructions. Cause Possible causes: 1. Contamination/ingress of dust 2. Short circuit due to ingress of water Remedy Clean printed circuit board under plastic housing and button "P": 1. Remove DSI (AR27.60-P-0901FRX) 2. Remove housing of DSI (see picture 1) 3. Remove cover around "P" button above printed circuit board (see picture 2) 4. Check printed circuit board: Liquid residues and/or contamination (cf. picture 3) 5. Check "P" button: Water residues and/or contamination (cf. picture 4) 6. Carefully clean the affected areas (using contact cleaner) 7. Reassemble and check the functionality 8. If fault code still present after rework -- follow available guided test remedy. |
| LI27.60-P-077704 | 2024-05-30. Service bulletin. POWER TRAIN. DSI selection lever module cannot be switched to park position "P" - malfunction of "P" button Note: Vehicle can still be placed into park by opening driver's door, or turning off ignition. Please refer to operator's manual section, "Engaging park position P," for additional instructions. Possible causes: 1. Contamination/ingress of dust 2. Short circuit due to ingress of water Clean printed circuit board under plastic housing and button "P": 1. Remove DSI (AR27.60-P-0901FRX) 2. Remove housing of DSI (see picture 1) 3. Remove cover around "P" button above printed circuit board (see picture 2) 4. Check printed circuit board: Liquid residues and/or contamination (cf. picture 3) 5. Check "P" button: Water residues and/or contamination (cf. picture 4) 6. Carefully clean the affected areas (using contact cleaner) 7. Reassemble and check the functionality 8. If fault code still present after rework -- open TIPS Case (send to Body/Chassis/Entertainment Inbox) |
| LI27.60-P-077704 | 2024-05-01. Service bulletin. POWER TRAIN. DSI selection lever module cannot be switched to park position "P" - malfunction of "P" button Note: Vehicle can still be placed into park by opening driver's door, or turning off ignition. Please refer to operator's manual section, "Engaging park position P," for additional instructions. Possible causes: 1. Contamination/ingress of dust 2. Short circuit due to ingress of water Clean printed circuit board under plastic housing and button "P": 1. Remove DSI (AR27.60-P-0901FRX) 2. Remove housing of DSI (see picture 1) 3. Remove cover around "P" button above printed circuit board (see picture 2) 4. Check printed circuit board: Liquid residues and/or contamination (cf. picture 3) 5. Check "P" button: Water residues and/or contamination (cf. picture 4) 6. Carefully clean the affected areas (using contact cleaner) 7. Reassemble and check the functionality 8. If fault code still present after rework -- open TIPS Case |
| LI54.10-P-069698 | 2023-01-05. Service bulletin. POWER TRAIN; ELECTRICAL SYSTEM. Complaint This LI does Not apply to 223 or 206 which use a different generation of 48V systems. Please follow the relevant guided tests for the 223 and 206. For 223 with fault code B1FCB97 follow LI54.10-P-073164. Various causes are possible. The faults listed in the various causes do not all have to be present at all times. Some of these complaints may overlap. Rely on the faults listed in the Cause section for identifying the correct Remedy. 1. No start 2. Yellow or red instrument cluster message for 48 V on-board electrical system battery (G1/3) 3. Limp home mode, overheating, A/C not blowing cold, or loss of acceleration 4. Check Engine Light Cause Cause 1: Software causes Intermittent No Starts with fault B183387 in DC/DC converter N83/1 Cause 2: Software causes Permanent No Start with fault B183349. May also have fault B183371. Cause 3: Hardware short circuit in 48V system causes fault B183319 in 48V battery. May also have fault B183371. Cause 4: Internal 48V battery Peltier cooling element failure causes fault B183397 |
| LI54.10-P-069698 | 2022-10-05. Service bulletin. POWER TRAIN. Complaint This LI does Not apply to 223 or 206 which use a different generation of 48V systems. Please follow the relevant guided tests for the 223 and 206. For 223 with fault code B1FCB97 follow LI54.10-P-073164. Various causes are possible. The faults listed in the various causes do not all have to be present at all times. Some of these complaints may overlap. Rely on the faults listed in the Cause section for identifying the correct Remedy. 1. No start 2. Yellow or red instrument cluster message for 48 V on-board electrical system battery (G1/3) 3. Limp home mode, overheating, A/C not blowing cold, or loss of acceleration 4. Check Engine Light Cause Cause 1: Software causes Intermittent No Starts with fault B183387 in DC/DC converter N83/1 Cause 2: Software causes Permanent No Start with fault B183349. May also have fault B183371. Cause 3: Hardware short circuit in 48V system causes fault B183319 in 48V battery. May also have fault B183371. Cause 4: Internal 48V battery Peltier cooling element failure causes fault B183397 Remedy Note: each of these remedies correspond to a specific cause. Make sure to match correct Cause with Remedy. Remedy 1: Update software in G1/3 (48V battery) using newest Xentry software and AddOns Remedy 2: 1. Xentry MUST be connected with VCI cable to correctly complete this remedy. 2. Complete guided test for B183349. 3. If guided test completes, vehicle starts, and drive cycles show no further symptoms, release vehicle. 4. If after guided test completes, Xentry states to replace 48V battery, replace only 48V battery. 5. If not, and symptoms are still present open a PTSS case. 6. If communication cannot be established with 48V battery perform physical layer check at 12V wiring to DCDC. If no abnormalities found, replace the 48V battery. 7. If guided test completes but a new fault code is present (such as B183319, B183371, etc.) follow the relevant Cause/Remedy for that fault in this LI. |
| LI2700P073124 | 2021-10-25. Service bulletin. EQUIPMENT ADAPTIVE/MOBILITY; EQUIPMENT; POWER TRAIN:AUTOMATIC TRANSMISSION. Transmission diagnosis using th eIntelligent Predictive Repair (IPR) tool. |