| 2069806/5 | 2024-04-06. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident. |
|---|---|
| 2061195/3 | 2023-11-07. Service bulletin. EQUIPMENT; ELECTRICAL SYSTEM. Telephone Functionality Complaint - Minimum Standards Required For Analysis Of Concerns. Customer statement / workshop findings: The feedback method within this TPI is required should a complaint of telephone functionality and/or quality be reported. Technical background: The minimum standards check list document within the Measure section is required to capture an accurate description of customer telephone issues. |
| 2069806/4 | 2023-10-06. Service bulletin. EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; STRUCTURE. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Condition HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin. - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident. |
| 2069806/3 | 2023-09-07. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. HVAC refrigerant leakage suspected Or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident. |
| 2036678.5 | 2023-02-03. Service bulletin. EQUIPMENT; ELECTRICAL SYSTEM. Speaker Replacement - Diagnostic Checks Technical Background: -There have been instances where door speakers have been changed under warranty for the complaint of sound distortion, yet when tested by ourselves and the supplier, no fault could be found with the returned unit. |
| 2051562.9 | 2022-11-08. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT. 12 Volt- Battery Condition Checks. Technical background For all 12 volt battery issues relating to warranty or a parts warranty claim, a DISS query MUST be raised prior to battery replacement, refer to the instructions within the Measure section of this TPI. |
| 2061195/1 | 2020-12-02. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT. Telephone Functionality Complaint - Minimum Standards Required For Analysis Of Concerns. Customer statement / workshop findings: The feedback method within this TPI is required should a complaint of telephone functionality and/or quality be reported. Technical background: The minimum standards check list document within the Measure section is required to capture an accurate description of customer telephone issues. |
| 2051562/6 | 2020-12-02. Service bulletin. EQUIPMENT ADAPTIVE/MOBILITY; EQUIPMENT; ELECTRICAL SYSTEM. All Models - 12 Volt Battery condition checks. Technical background For all 12 volt battery issues relating to warranty or a parts warranty claim, a DISS query MUST be raised prior to battery replacement, refer to the instructions within the Measure section of this TPI. |
| 2058173/2 | 2020-11-07. Service bulletin. EQUIPMENT; ELECTRICAL SYSTEM. Electrical switch replacement guidelines. Customer statement/workshop findings: Electrical switch suspected as defective This TPI is not applicable to suspected faulty control units or any component related to the passive restraint system in particular the airbag system Technical background: Prior to replacing an electrical switch refer to the Measure section of this TPI |
| 2042104/1 | 2020-01-17. Service bulletin. EQUIPMENT; ELECTRICAL SYSTEM. Telephone Functionality Complaint - Minimum Standards Required For Analysis Of Concerns Customer statement / workshop findings: An improved feedback method is required should a complaint of telephone functionality / quality be reported. Technical background: A minimum standards document is required to capture an accurate description of customer telephone issues. Measure: The attached document should be completed and attached to the relevant DISS query, this will allow a full understanding of the customer complaint and the circumstances in which the complaint becomes apparent. |
| SB-20362667-1 | 2016-04-26. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. SUMMARY TO BE PROVIDED ON A FUTURE DATE. |
| TB-10-01-01-02 | 2010-11-20. Service bulletin. EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL; UNKNOWN OR OTHER. BENTLEY: A CONDITION HAS BEEN IDENTIFIED THAT CAN COMPROMISE THE SURFACE FINISH OF THE PIPE SUPPLYING LUBRICANT TO THE TURBOCHARGERS. IF LEFT UNDETECTED THE PIPE MAY CORRODE AND, IN EXTREME CASES, RESULT IN FLUID LOSS. NO MODEL YEARS LISTED. *PE |