2057841/52026-09-09. Service bulletin. STRUCTURE:BODY; VISIBILITY/WIPER. Windscreen replacement criteria whilst under manufacturers warranty.
2078373/42026-09-03. Service bulletin. VISIBILITY/WIPER; STRUCTURE:BODY; ELECTRICAL SYSTEM. Sunroof blind not retracting | Bentayga Series. Customer may report that the sunroof blind is stuck in the closed position and cannot be opened using interior controls. The Sunroof blind is stuck due to uneven/ruffled or crumped during open or closing
2071190/42026-08-01. Service bulletin. ENGINE; VISIBILITY/WIPER; ELECTRICAL SYSTEM. HVAC failing to cool | DTC B16A1F0 in diagnostic address 00C5 | Bentayga Series (Hybrid).
2071190/32026-01-08. Service bulletin. ENGINE; VISIBILITY/WIPER; ELECTRICAL SYSTEM. HVAC failing to cool | DTC B16A1F0 in diagnostic address 00C5 | Bentayga Series (Hybrid) | 23MY - 25MY.
2069806/72025-10-07. Service bulletin. VISIBILITY/WIPER; ELECTRICAL SYSTEM; STRUCTURE:BODY. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines
2050542/82025-07-08. Service bulletin. ELECTRICAL SYSTEM; EXTERIOR LIGHTING; VISIBILITY/WIPER. Front Exterior Lighting Steamed Up/Leaks | 12-24MY.
2069806/62025-07-08. Service bulletin. VISIBILITY/WIPER; ELECTRICAL SYSTEM. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines.
2071190/22025-05-07. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY/WIPER; STRUCTURE:BODY. HVAC failing to cool | DTC B16A1F0 in diagnostic address 00C5 | Bentayga Series (Hybrid) | 23MY - 25MY. Customer statement: HVAC system is not cooling. Workshop findings DTC B16A1F0 - Refrigerant shut-off valve Icing - water load too high, evident within diagnostic address 00C5.
2069806/52024-04-06. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident.
2051519/132023-12-06. Service bulletin. VISIBILITY; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; ELECTRICAL SYSTEM. HVAC distribution/operational issues - HVAC Motor defect DTCs logged. Customer statement / workshop findings: - HVAC distribution/operational issues - HVAC motor defect (DTCs) evident within address 08 - Climatronic control unit, the DTCs can be static or Intermittent Technical background: Where VIN applicable the operative MUST first conduct Service Campaign EB28 (Bentayga) or EB29 (New Continental GT/GTC).
2060458.32023-11-08. Service bulletin. VISIBILITY; ELECTRICAL SYSTEM; STRUCTURE. Water Ingress onto the front reading light Customer Statement: -Water drips from the front interior light. The water drips directly from the electric drive of the front sun roof motor.
2050542.72023-11-06. Service bulletin. ELECTRICAL SYSTEM; EXTERIOR LIGHTING; VISIBILITY. Service info: body/equipment: front exterior lighting steamed up/leaks Customer Statement: -1. The lenses of the headlights (illustration 1a) /front fog lamps (illustration 1b) are steamed up/damp from the inside with minor drips. 2. Water is in the headlight (illustration 2a) / front fog lamp (illustration 2b), big drips.
2069806/42023-10-06. Service bulletin. EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; STRUCTURE. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Condition HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin. - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident.
2071190/12023-09-07. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; EQUIPMENT. Bentayga Hybrid - HVAC not cooling - DTC B16A1F0 is evident within diagnostic address 00C5. Customer statement / workshop findings: Customer statement HVAC system is not cooling Workshop findings: DTC B16A1F0 - Refrigerant shut-off valve Icing - water load too high, evident within diagnostic address 00C5 Technical background: Upon receipt of a customer complaint relating to HVAC system not cooling and DTC B16A1F0 is evident, please refer to the Measure section of this TPI.
2069806/32023-09-07. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. HVAC refrigerant leakage suspected Or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident.
2069806/22023-09-07. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; VISIBILITY; ELECTRICAL SYSTEM. HVAC refrigerant leakage suspected Or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident. In the event that HVAC cleaning products are required, these MUST be sourced locally. Before using the cleaner the operative must inform the customer of the product which will be used, a neutral fragrance cleaner should be used as the customer may not like the smell of the cleaner should a fragranced product be used Please ensure all supporting information is included within the DISS query when requesting permission to clean the HVAC system including clear photographs and/or videos showing the reported issue, should the required information not be supplied the warranty claim could be cancelled.
2069806.12023-05-05. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; ELECTRICAL SYSTEM; ENGINE AND ENGINE COOLING. HVAC Refrigerent Leakage - Diagnosis Guidelines Customer Statement: -HVAC not cooling or HVAC cooling less than expected

The summaries are NHTSA's. Each bulletin's page links NHTSA's copy of the manufacturer's document.