TSB0058232023-10-16. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM:REFRIGERANT HOSES AND FITTINGS. TSB: The air conditioning dye injection tool kit has been developed to aid in identifying the location of air conditioning refrigerant leaks. Follow the procedures outlined in this service bulletin to aid in locating, inspecting, and repairing refrigerant leaks
T-SB-0004-22 Rev2022-12-19. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. TSB: Some 2016 ? 2023 model year Tacoma vehicles may exhibit what customers describe as a 1 ? 3-second whistle noise from the HVAC system when the air conditioning system is ON. The whistle noise may occur as the compressor cycles on and off and is more prevalent with increased engine RPM during hot ambient temperatures. Follow the Repair Procedure in this bulletin to address this condition.
T-SB-0004-222022-02-14. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. TSB: Some 2016 ? 2022 model year Tacoma vehicles may exhibit what customers describe as a 1 ? 3-second whistle noise from the HVAC system when the air conditioning system is ON. The whistle noise may occur as the compressor cycles ON/OFF and is more prevalent with increased engine RPM during hot ambient temperatures. Follow the Repair Procedure in this bulletin to address this condition.
T-SB-0080-19 Rev2021-09-13. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. TSB: Some 2006 ? 2022 model year Toyota vehicles in particular geographic areas may exhibit a condition where the HVAC evaporator drain hose has become obstructed with an insect nest. An insect repellent drain hose tip (ARINIX® Tip) is available to help minimize future occurrences of this environmental condition. For some models, a new drain hose is required to properly fit the ARINIX® Tip. Follow the procedures in this bulletin for proper handling and installation of this optional service part.
T-SB-0063-18 Obs2020-10-26. Service bulletin. ENGINE AND ENGINE COOLING; EQUIPMENT:APPLIANCE:AIR CONDITIONER. TSB: OBSOLETE NOTICE September 22, 2020: This bulletin is now obsolete. Please see T-SB-0093-20.
T-SB-0093-202020-10-26. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. TSB: Some 2016 ? 2020 model year Tacoma vehicles may exhibit a condition where the air conditioning system shuts down and stops blowing cool air during periods of extended engine idle with ambient temperatures greater than 100°F. Follow the Repair Procedure in the bulletin to address this condition.
T-SB-0063-18-Rev2019-03-25. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; POWER TRAIN. TSB: REVISION NOTICE February 25, 2019 Rev1: ? Applicability has been updated to include 2019 model year Tacoma vehicles and engine and transmission types. ? The Warranty Information section has been updated. ? The Repair Procedure section has been updated with the addition of step 84. Any previous printed versions of this bulletin should be discarded. Some 2016 ? 2019 model year Tacoma vehicles may exhibit a condition where the air conditioning system shuts down and stops blowing cool air during periods of extended engine idle with ambient temperatures greater than 100°F. Follow the Repair Procedure in the bulletin to address this condition.
T-TT-0468-17-Rev2019-03-25. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. TT: HVAC drain tube is found to be blocked/clogged.
J0N-Technical In2018-12-03. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; EQUIPMENT. Technical Instructions: TECHNICAL INSTRUCTIONS FOR SPECIAL SERVICE CAMPAIGN J0N HVAC BLOWER MOTOR CERTAIN 2016-2017 MODEL TACOMA
J0N-Dealer Packa2018-12-03. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; EQUIPMENT. Dealer Package: There is a possibility that the blower motor fan hub in the involved vehicles was produced with improper dimensions. A blower motor fan hub with improper dimensions may develop a crack over time. If a vehicle is continuously operated with this condition, the damage may worsen, leading to an abnormal noise and eventually an inoperable blower motor fan.
J0N-Region Lette2018-12-03. Service bulletin. EQUIPMENT; EQUIPMENT:APPLIANCE:AIR CONDITIONER. Region Letter: There is a possibility that the blower motor fan hub in the involved vehicles was produced with improper dimensions. A blower motor fan hub with improper dimensions may develop a crack over time. If a vehicle is continuously operated with this condition, the damage may worsen, leading to an abnormal noise and eventually an inoperable blower motor fan.
J0N-Region Email2018-12-03. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; EQUIPMENT. Region Email: There is a possibility that the blower motor fan hub in the involved vehicles was produced with improper dimensions. A blower motor fan hub with improper dimensions may develop a crack over time. If a vehicle is continuously operated with this condition, the damage may worsen, leading to an abnormal noise and eventually an inoperable blower motor fan.
J0N-Technical In2018-11-26. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Technical Instructions: TECHNICAL INSTRUCTIONS FOR SPECIAL SERVICE CAMPAIGN J0N HVAC BLOWER MOTOR CERTAIN 2016-2017 MODEL TACOMA
J0N-Dealer Packa2018-11-26. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Dealer Package: There is a possibility that the blower motor fan hub in the involved vehicles was produced with improper dimensions. A blower motor fan hub with improper dimensions may develop a crack over time. If a vehicle is continuously operated with this condition, the damage may worsen, leading to an abnormal noise and eventually an inoperable blower motor fan.
J0N-Region Lette2018-11-26. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Region Letter: There is a possibility that the blower motor fan hub in the involved vehicles was produced with improper dimensions. A blower motor fan hub with improper dimensions may develop a crack over time. If a vehicle is continuously operated with this condition, the damage may worsen, leading to an abnormal noise and eventually an inoperable blower motor fan.
J0N-Region Email2018-11-26. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Region Email: There is a possibility that the blower motor fan hub in the involved vehicles was produced with improper dimensions. A blower motor fan hub with improper dimensions may develop a crack over time. If a vehicle is continuously operated with this condition, the damage may worsen, leading to an abnormal noise and eventually an inoperable blower motor fan.
T-SB-0063-182018-08-20. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. TSB: Some 2016 ? 2018 model year Tacoma vehicles may exhibit a condition where the air conditioning system shuts down and stops blowing cool air during periods of extended engine idle with ambient temperatures greater than 100°F. Follow the Repair Procedure in the bulletin to address this condition.
T-TT-0441-172018-07-02. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. TT: During previous air conditioning service, leakage prevention agent (A/C stop leak) may have been added to the A/C system. Adding stop leak products to the A/C system is not a recommended or approved Toyota repair process. During A/C service, moisture enters the A/C system, and can react with the previously added A/C stop leak, forming a gelatinous substance. The gel substance that forms can cause the A/C compressor to bind and or seize.