Service bulletins for the 2025 Mercedes-Benz eSprinter
A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.
6 on file from NHTSA, as of 2026-10-19.
By type
By component
By trouble code
Only bulletins with component: Electrical system are shown. Show all
| LI54_10-N-080879_1_en | 2026-09-03. Service bulletin. ELECTRICAL SYSTEM. AC and DC Charging inoperative with no failure codes in the relevant control units Complaint AC and DC charging are not possible. The white LED on the charging inlet completely goes OFF after plugging in the charging cable. Cause Control pilot (CP) circuit in DCB (N24/6: Charger (DC)) might be not functioning due to electrical overstress from EVSE (Electric Vehicle Supply Equipment | Charging Station). Remedy Refer to the charging cable actual values in DCB (N24/6). |
|---|---|
| 2026050008 | 2026-07-02. Service campaign. ELECTRICAL SYSTEM. On certain Mercedes-Benz eSprinter vehicles, the software for the DC Box control unit does not correspond to the current series production configuration. |
| LI47-70-N-080294 | 2026-04-02. Service bulletin. ELECTRICAL SYSTEM. eSprinter model series 907: Intermittent no-start condition Complaint Intermittent no-start condition; partial restart without "Ready" status in display. Concern may be rectified after bus idle and/or circuit 30 deep reset. Cause As a result of inaccuracies in Battery Management System measurements, the BMS may record the following fault codes: P0ABD00 - Battery voltage sensor A in the hybrid/high-voltage battery module has a short circuit to positive. P0B171C - Battery voltage sensor B in the hybrid/high-voltage battery module has a short circuit to positive. The vol-tage value is outside the permissible range P181D12 - The reference voltage at output A has exceeded the limit value. There is a short circuit to positive Remedy Perform a software update of control unit G1/9 - battery management system (BMS) (BMS907) |
| LI47.70-N-079913 | 2025-12-03. Service bulletin. ELECTRICAL SYSTEM. Vehicle not starting after DC charging Complaint Vehicle will not start after DC charging Warning in the instrument cluster related to High-voltage on board electrical system The following fault codes related to stuck contactor can be found in the High Voltage Control units : PTCU - N127 (Powertrain control unit) • P154900 - There is a warning due to overcurrent in the charging system of the high-voltage electric circuit. • P154A00 - There is a warning due to a detected crash event at standstill. • P154B00 - There is a warning due to a stuck contactor. DCB223 - N116/5 (Direct current charge connection unit) • P0E8929 - The input current of the on-board DC charging connection unit is too high. There is an invalid signal. • P2BC500 - The contact ''Positive terminal'' of the contactor in the on-board DC current charge-connection unit is jammed closed • P2BCC00 - The contact ''Negative terminal'' of the contactor in the on-board DC current charge-connection unit is jammed closed. Remedy • Check for a new software availability for DCCU (N24/6 - Direct Current Charge connection Unit). If a new software is available, update the software first. • Reset contactor fault through special procedure without password. ( N24/6 >> Special Procedure >> Resetting of contactor fault.) |
The summaries are NHTSA's. Each bulletin's page links NHTSA's copy of the manufacturer's document.