WenmarOpen by Wenmar Pro

Service bulletins for the 2021 Freightliner Sprinter

A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.

87 on file from NHTSA, as of 2026-10-19.

About P3006 on the 2021 Freightliner Sprinter: what the code means, and the bulletins and recalls about the same components.

By type

By component

By trouble code

By topic

Only bulletins with trouble code: P3006 are shown. Show all

Bulletins, newest first
LI49-20-N-0759952026-04-02. Service bulletin. UNKNOWN OR OTHER. Vehicles with SCR Generation 4: SCR/AdBlue® warning message cannot be reset with fault code P13DF00 or P300685 Complaint SCR or AdBlue warning message cannot be reset. All fault codes in the AdBlue (SCR) control unit have been processed and corrected, however fault codes P13DF00 or P300685 remain active and stored. Cause The procedure for resetting the SCR or AdBlue warning message with XENTRY Diagnosis has not been carried out. Note: If AdBlue quality or concentration related fault codes are present, such as P300494, P203B31, or P206B31, complete the applicable diagnostic procedure first. This includes the thaw, mixing drive, and retest requirements in LI49.20-N-080376 and the detailed diagnosis and re-pair steps in LI49.20-N-078838 as applicable. Do not attempt to reset the SCR or AdBlue warning message until the underlying fault condition has been corrected. Remedy Note: Do not replace any parts for an incorrectly executed reset procedure. 1. Connect the battery charger •Maintain adequate voltage throughout the procedure per applicable guidance. 2. Connect the diagnostic device •Use the latest version of XENTRY Diagnosis and Add-Ons. 3. Reset the SCR or AdBlue warning message using XENTRY Diagnosis •Quick test view → N118/5 – Selective Catalytic Reduction (SCR GEN4) → Special processes → Reset SCR/AdBlue® warning message. Note: Ensure all 5 listed processes are completed successfully, indicated by Actual value: "successfully completed". 4. Complete the disconnect and sleep mode initiation procedure •Disconnect XENTRY. •Refer to manual AD00.00-D-2000-06TS for the correct procedure to disconnect the diagnostic device from Model 907. •Disconnect the Battery Charger •Refer to manual AR54.10-D-1127TS for instructions on safely disconnecting the battery charger from Model 907. •Turn off the ignition. •Remove the key. •Lock the vehicle and wait approximately 15 minutes to allow the CAN bus system to enter sleep mode. 5. Post sleep mode vehicle start •After the 15-minute waiting period, start the vehicle. Note: The "starts remaining" message will remain on the Instrument Cluster (IC), but the vehicle will not be in the 5mph de-rate mode. 6. Drive for system self-test •Drive the vehicle for 5 to 10 miles to enable the SCR system to perform a self-test. Note: During the warning reset process, ensure the outside temperature sensor is reading above 10 degrees Fahrenheit. If not, keep the vehicle inside and repeat the reset. The vehicle may need to be driven to allow NOx sensors and the SCR system to complete their self-test before fault codes can be stored and then cleared. 7. Confirm and erase fault codes •Verify warning messages. •Ensure relevant fault codes are stored. •Erase fault memory if necessary. 8. Disconnect the Diagnostic Device •Refer to manual AD00.00-D-2000-06TS for the correct procedure to disconnect the diagnostic device from Model 907. 9. Disconnect the Battery Charger •Refer to manual AR54.10-D-1127TS for instructions on safely disconnecting the battery charger from Model 907.
LI4920N0759952026-03-03. Service bulletin. ENGINE. Vehicles with SCR Generation 4: SCR/AdBlue® warning message cannot be reset with fault code P13DF00 or P300685 Complaint Vehicles with SCR Generation 4: SCR/AdBlue® warning message cannot be reset. Information: All fault codes in the AdBlue® (SCR) control unit have been processed and corrected; however, fault codes P13DF00 and P300685 remain active and stored in the AdBlue® (SCR) control unit. Cause The procedure for resetting the SCR/AdBlue® warning message with XENTRY Diagnosis has not been carried out. Information: Before resetting the SCR/AdBlue® warning message for SCR Generation 4, the AdBlue® system must be in proper working condition and tested.
LI49.20-N-0759952026-02-03. Service bulletin. ENGINE. Complaint Vehicles with SCR Generation 4: SCR/AdBlue® warning message cannot be reset. Information: All fault codes in the AdBlue® (SCR) control unit have been processed and corrected; however, fault codes P13DF00 and P300685 remain active and stored in the AdBlue® (SCR) control unit. Cause The procedure for resetting the SCR/AdBlue® warning message with XENTRY Diagnosis has not been carried out. Information: Before resetting the SCR/AdBlue® warning message for SCR Generation 4, the AdBlue® system must be in proper working condition and tested.
LI49.20-N-0759952025-04-03. Service bulletin. ENGINE. Vehicles with SCR Generation 4: SCR/AdBlue® warning message cannot be reset with fault code P13DF00 or P300685 Complaint: Vehicles with SCR Generation 4: SCR/AdBlue® warning message cannot be reset. Information: All fault codes in the AdBlue® (SCR) control unit have been processed and corrected; however, fault codes P13DF00 and P300685 remain active and stored in the AdBlue® (SCR) control unit. Cause: The procedure for resetting the SCR/AdBlue® warning message with XENTRY Diagnosis has not been carried out. Information: Before resetting the SCR/AdBlue® warning message for SCR Generation 4, the AdBlue® system must be in proper working condition and tested.

The summaries are NHTSA's. Each bulletin's page links NHTSA's copy of the manufacturer's document.