WenmarOpen by Wenmar Pro

Service bulletins for the 2014 BMW i8

A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.

212 on file from NHTSA, as of 2026-10-19.

By type

By component

By topic

Only bulletins with component: Heating and air conditioning are shown. Show all

Bulletins, newest first
B6413182019-02-25. Service bulletin. EQUIPMENT; EQUIPMENT:APPLIANCE:AIR CONDITIONER. INSUFFICENT AIR COMING FROM VENTS. Air quantity from vents does not chance with blower speed.
B6408162018-12-10. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Reduced or No HVAC Heat Output. I12 & F30 PHEV - The heat is not functioning during electric driving and/or the heat output is reduced or fluctuating when driving with the combustion engine. I01 - The heat is not functioning at all. The issue can occur sporadically for all vehicles and will not have any associated fault codes. IHKA software with I-Level: I01, I12I001-15-11-504 F30 PHEV F020-15-11-505
B1227152018-12-10. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; ELECTRICAL SYSTEM; ELECTRICAL SYSTEM:SOFTWARE. This Service Information bulletin supersedes SI B12 27 15 dated November 2015 SUBJECT Service Engine Soon (MIL) - IHKA FC 801375 & 8013A3. The Service Engine Soon light (MIL) is currently or intermittently illuminated in the instrument cluster and one or both of the fault codes below are stored in the Automatic Climate Control (IHKA). 801375 - Electric auxiliary heater (high voltage) is stored: Temporary fault detected after software reset CAUSE: IHKA software or Electric Heater (EH).
B6507092018-12-10. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Whistling Noise Coming from the Center Vent - A/C is Off . A very high pitched whistling or beeping noise is heard coming from the center vents. The flow of refrigerant through the expansion valve at certain temperature differentials.
B6411182018-11-26. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. STATIONARY CLIMATE CONTROL NOT WORKING AFTER HIGH VOLTAGE CHARGING. After the high voltage (HV) charging procedure, the stationary climate control (aka preconditioning) does not work. This is part of the normal design. There is no fault or defect.
B6413162018-11-05. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. "A/C FAILURE: FC 801252 ELECTRIC A/C COMPRESSOR: INTERNAL FAULT DETECTED. Air conditioning (A/C) failure with IHKA fault code ""801252 - Electric A/C compressor: Internal fault detected"". IHKA software fault in the versions detailed in the following table: ModelISTA/P versionIntegration levelF153.57.3F025-15-11-505F303.57.2F020-15-11-504I01, I123.57.0I001-15-11-501"
B6413162018-05-07. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; EQUIPMENT:ELECTRICAL. A/C FAILURE: FC 801252 ELECTRIC A/C COMPRESSOR: INTERNAL FAULT DETECTED: Air conditioning (A/C) failure with IHKA fault code "801252 - Electric A/C compressor: Internal fault detected".

The summaries are NHTSA's. Each bulletin's page links NHTSA's copy of the manufacturer's document.