Service bulletins for the 2013 BMW 750Li
A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.
348 on file from NHTSA, as of 2026-10-19.
By type
By component
By trouble code
By topic
Only bulletins with component: Electrical system are shown. Show all
| 652113 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM; SEATS. When Unlocking with Comfort Access the Outside Door Mirrors Are in the Wrong Position. The vehicle is locked with one remote key and then enters sleep mode. The vehicle is then unlocked using one of the outside door handles with the second remote key. The outside door mirrors do not move to the correct position. The seats do move into the correct position. CAUSE Software error in driver's seat module |
|---|---|
| 610314 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM. Check Control Messages Related to Battery Charge During Cold Ambient Temperatures. On cold days with an outside ambient temperature of less than 15°F, customers may notice a check control message related to the battery that is displayed on the instrument cluster and the control information display. Under these conditions, the vehicle starts. Various power management faults can be stored: * 213901 - Power management: Reduction or shutdown of individual electrical consumer * 8040BD - Reset or deactivation of Terminal 30F * 8040B9 - De-activation of terminal 30B: Top start capability limit reached * 8020E8 - Reset or deactivation of terminal 30F * 800E89 - FRM: start capability limit reached with lights active during stationary mode * 93076B - Deactivation of terminal 30B: upper start capability limit reached * 93076A - Deactivation of terminal 15: upper start capability limit reached, but deactivation preventer active * 93076C - Deactivation of terminal 30B: upper start capability limit reached, but deactivation preventer or legal loads active * 930769 - Deactivation of terminal 15: upper start capability limit reached Note: When the outside temperatures drop below 46°F, the charging system is switch to full charge. CAUSE * The check control message (ID 229) is caused by a heavily discharged battery. * The check control message is triggered when the current state of charge (SoC) of the battery approaches the minimum SoC that is required to start the vehicle (start capability limit). * In low outside ambient temperatures, the start capability limit of the vehicle is higher. Therefore it takes more energy from the battery to start a cold engine. * Without the early warning of the check control message, the current state of charge would drop below the start capability limit and the vehicle would not start. * The vehicle's intelligent power management system actively takes measures to increase the charge of the battery, such as increasing idle speed and reducing or shut |
| 840314 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM. iPhone: Connection Failures with iOS 7. There are various connectivity failures with the iPhone using iOS 7. Some examples are listed below: * Call disconnection * Contact List incomplete * General connection failures CAUSE Apple software iOS 7 and its variants. |
| 630514 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM; EXTERIOR LIGHTING:HEADLIGHTS; EXTERIOR LIGHTING. "Adaptive Headlight Malfunction in Cold Weather. * In very cold weather conditions (32ºF or below) with the light switch in the automatic position, the CCM (Check Control Message) ""Adaptive headlight malfunction"" is displayed. * When the CC message is displayed, all the lights continue to function. * When switching the headlights to high beam and the headlight unit is cold, the mechanism inside the headlight is too stiff to move. Software error in TMS 3 (headlight driver module AHL, xenon headlight)" |
| 122514 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM. N63T: Improvements to Bosch Spark Plug. Various engine performance symptoms could occur if the spark plug insulator becomes damaged: * The Service Engine Soon (MIL) may be on with rough running and misfire fault(s) stored. * Intermittent performance or rough running without a relevant DME fault stored. The spark plug insulator could be damaged in cases of combustion faults such as misfiring, ignition knock or super knocking conditions. |
| 840114 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT:ELECTRICAL. ConnectedDrive/BMW Assist System Information and Availability. ConnectedDrive features are partially or completely inoperative. Examples of some of these features are listed below: * BMW Assist Inoperative ? SOS call ? Roadside Assistance call * My BMW Remote App * BMW Online - Google local search * Concierge CAUSE The Electronic Subscriber Agreement (ESA) is inactive. * No active contract for ConnectedDrive features Offboard Availabilty (Backend) system issues * The external network was/is inoperative. * No data is sent to the vehicle. |
| 840913 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM. My BMW Remote iPhone App No Longer Controls Headlight or Horn. After programming the vehicle with ISTA/P 2.49.x or higher, the headlight and the horn can no longer be controlled using the My BMW Remote App from an iPhone. I-Level F001-13-03-501 or F010-13-03-501 and higher Note: The lock and unlock function via the App works as designed. CAUSE A software error in the central gateway (ZGW) control unit |
| 620613 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM. The Condition Based Service (CBS) due date is reset to 01/2000 and cannot be updated for: * Oil Service * Check Vehicle Note: No fault code is stored Software error in the Instrument Cluster |
| 840913 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM. My BMW Remote iPhone App No Longer Controls Headlight or Horn. After programming the vehicle with ISTA/P 2.49.x or higher, the headlight and the horn can no longer be controlled using the My BMW Remote App from an iPhone. I-Level F001-13-03-501 or F010-13-03-501 and higher Note: The lock and unlock function via the App works as designed. CAUSE A software error in the central gateway (ZGW) control unit |
| 652513 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM. "ConnectedDrive/BMW ASSIST Features Are Inoperative. ConnectedDrive features are partially or completely inoperative. * No traffic information (RTTI / ARTTI) * BMW ASSIST ""My Info"" service doesn't work. CAUSE The Electronic Subscriber Agreement (ESA) is inactive. * No active contract for ConnectedDrive features Offboard Availability (Backend) system issues * The external network was/is inoperative. * No data is sent to the vehicle." |
| 652413 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM. Headunit-High: INITIAL Enabling Code Is Not Accepted Via I-Drive. INFORMATION Do not replace any parts. NOTE: First time activation of the navigation system should always be performed during the Quality Certification 1 (QC1) Pre-Delivery Check, with the vehicle connected to the diagnosis system ISTA. Refer to SI B65 30 09. Connect the vehicle to the diagnosis system ISTA and activate the navigation system. The code is entered when running the QC1 Pre-Delivery Check test module. Refer to SI B09 04 09. IMPORTANT: No programming is required. WARRANTY INFORMATION Not applicable since the first time activation of the navigation system is part of the QC1 process and cannot be claimed separately. |
| 630514 | 2018-11-13. Service bulletin. EXTERIOR LIGHTING; ELECTRICAL SYSTEM. "Adaptive Headlight Malfunction in Cold Weather. * In very cold weather conditions (32ºF or below) with the light switch in the automatic position, the CCM (Check Control Message) ""Adaptive headlight malfunction"" is displayed. * When the CC message is displayed, all the lights continue to function. * When switching the headlights to high beam and the headlight unit is cold, the mechanism inside the headlight is too stiff to move. CAUSE Software error in TMS 3 (Headlight driver module AHL xenon light)" |
| 620713 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM. Instrument Cluster: Backlight Stays On After Ignition Off. The backlighting in the instrument cluster stays on after ignition off. ??No fault code is stored Software error in the instrument cluster introduced with software I-level 13-07-501 or higher (ISTA/P 2.50.0 or higher) in July 2013 |
| 612213 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM. """Increased battery discharge!"" CC Message upon Startup. CAUSE A software error in the Intelligent Battery Sensor causes an incorrect State of Charge (SoC) to be stored in the DME. The power management system then interprets this as a heavily discharged battery and informs the customer via a CC message. In reality, the battery does not have a problem." |
| B621215 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM: INSTRUMENT CLUSTER/PANEL. Instrument Cluster Outside Temperature Display Implausible. INFORMATION This service information bulletin provides technical, diagnostic and/or repair-related information. Eligible and Covered Work/Repairs To submit a claim for the repair of a verified defect in materials or workmanship, please following the established and applicable warranty policy and procedures together with the using corresponding defect code and labor operations provided in the KSD2. |
| B613014 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM. "?SI B61 30 14December 2015 General Electrical SystemsTechnical Service This Service Information bulletin supersedes SI B61 30 14 dated July 2015. designates changes to this revision SUBJECT BMW Maintenance Program: 12-Volt Battery Replacement Measure. INFORMATION This bulletin outlines a customer satisfaction measure that has been designed exclusively for the BMW vehicles listed above. It involves the replacement of the 12-volt battery as a preventive maintenance measure. This 12-volt battery replacement measure is: Effective for repairs dated on or after January 1, 2015. Applicable to vehicles that are still covered by the BMW Maintenance Program. This program is valid for 4 years or 50,000 miles, whichever occurs first. The calculation is based on the current date of repair. It is ""applicable"" when the 12volt battery was not replaced within the last 12 months. You can then perform the battery replacement as outlined below. Please check the warranty claim history for the specific vehicle in the DCSnet Warranty Vehicle Inquiry to confirm the battery was not already replaced within the previous 12 months. " |
| B650915 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT:ELECTRICAL. HU-H: Headunit Resets Intermittently or Permanently. The HU-H (Headunit-High) resets intermittently or permanently. ? The display is inoperative and there is no audio output ? Automatic system start-up after a couple of seconds CAUSE Software error in the HU-H |
| B621015 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM: INSTRUMENT CLUSTER/PANEL. "Instrument Cluster display inoperative FC B7F689. The Instrument Cluster (Kombi) is intermittently inoperative with fault code B7F689 ""display backlighting and graphics PCB switched off"" stored. Kombi software." |
| B620715 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM. "Instrument Cluster display is partially blank. INFORMATION Covered under the terms of the BMW New Vehicle Limited Warranty for Passenger Cars and Light Trucks or the BMW Certified Pre-Owned Program. If you are using a Main labor code for another repair, use the Plus code labor operation 00 00 556 instead. Refer to KSD2 for the corresponding flat rate unit (FRU) allowances. Vehicle Programming and Encoding If a control module was working properly and it fails to program correctly or requires initialization, please claim this additional work with the applicable KSD2 labor operations under the defect code listed above. The diagnosis and repair of vehicles ""arriving"" with failed control modules or stored faults which will cause them to fail during programming cannot be claimed under the defect code listed in this bulletin. Other Repairs If other eligible and covered work is performed ""prior"" to programming and coding the vehicle, claim this work with the applicable defect code and labor operations listed in KSD2. " |
| B620715 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM: INSTRUMENT CLUSTER/PANEL. Instrument Cluster display is partially blank. The Instrument Cluster (Kombi) lower display may be intermittently blank. The Board Computer, Ambient Temperature and Check Control Messages will not display. Instrument Cluster software error. |
| B620315 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM; STRUCTURE:BODY:DOOR. This Service Information bulletin supersedes SI B62 03 15 dated April 2015. designates changes to this revision SUBJECT Door Open Message Displayed, Even Though Door Is Closed. While driving, a CCM (Check Control Message) indicates the doors are open, even though they are closed. Also, sometimes the gong will sound and the interior lights will go on and off. The FRM (Footwell Module) sees an incorrect door lock status caused by voltage variations in the door locks. |
| B620415 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM: INSTRUMENT CLUSTER/PANEL; ELECTRICAL SYSTEM:SOFTWARE. Service Action: Programming Control Units. Sporadically the vehicle cannot be started, due to a discharged battery caused by a software glitch in the instrument cluster. |
| B613014 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM:12V/24V/48V BATTERY. "BMW Maintenance Program: 12-Volt Battery Replacement Measure. INFORMATION This bulletin outlines a customer satisfaction measure that has been designed exclusively for the BMW vehicles listed above. It involves the replacement of the 12-volt battery as a preventive maintenance measure. This 12-volt battery replacement measure is: ? Effective for repairs dated on or after January 1, 2015. ? Applicable to vehicles that are still covered by the BMW Maintenance Program. This program is valid for 4 years or 50,000 miles, whichever occurs first. ? The calculation is based on the current date of repair. It is ""applicable"" when the 12-volt battery was not replaced within the last 12 months. You can then perform the battery replacement as outlined below. Please check the warranty claim history for the specific vehicle in the DCSnet Warranty Vehicle Inquiry to confirm the battery was not already replaced within the previous 12 months." |
| 610313 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM; ELECTRICAL SYSTEM:12V/24V/48V BATTERY. "This Service Information bulletin supersedes SI B61 03 13 dated August 2013. designates changes to this revision SUBJECT High Battery Discharge Warning: Battery Needs Replacement. After the vehicle is started, a Check Control message ""High Battery Discharge Warning"" is displayed in the Central Information Display (CID). Various power supply and power management faults are stored, including the following: CAS - ""930769 Deactivation of terminal 15: upper startability limit reached"" CAS - ""93076A Deactivation of terminal 15: upper startability limit reached, but deactivation preventer or legal load/consumer active"" CAS - ""93076B Deactivation of terminal 30B: upper startability limit reached"" CAS - ""93076C Deactivation of terminal 30B: upper startability limit reached, but deactivation preventer or legal load/consumer active"" JBE - ""8020E8 Reset or deactivation of terminal 30F"" DME - ""213901 Power management: reduction or deactivation of individual electrical loads/consumers"" CAUSE The battery has become heavily discharged or is faulty. The following reasons can contribute to a prematurely failing battery: z Unfavorable driving profile - excessive short trips z Excessive terminal 30B after run - normal coolant pump or electric fan operation z Extremely cold temperatures z Vehicle faults - closed circuit draw, sleep mode preventer or frequent wakeups." |
| 120415 | 2018-11-13. Service bulletin. ELECTRICAL SYSTEM; ENGINE. SUBJECT DME Internal and Valvetronic Faults Set at Cold Ambient Temperatures. The Service Engine Soon light (MIL) can be illuminated with the erroneous internal and Valvetronic faults stored in the DME. The MIL will only come on if the fault has been detected on two (or more) consecutive drive cycles. The following fault codes may be stored in the DME: E Seriesz 36AE - DME, internal fault, Valvetronic: Current implausible One or more of the following secondary faults may also be stored: z 2DE2 - Valvetronic, actuation, voltage phase: Line disconnection z 2DE3 - Valvetronic, actuation, volt phase: Line disconnection z 2DE4 - Valvetronic, actuation, volt phase: Line disconnection F Seriesz 1F0905 - DME, internal fault, Valvetronic: Current implausible One or more of the following secondary faults may also be stored: z 135B10 - Valvetronic, actuation, voltage phase: Line disconnection z 135B11 - Valvetronic, actuation, volt phase: Line disconnection z 135B12 - Valvetronic, actuation, volt phase: Line disconnection Engine performance and driving characteristics are not affected. DME software diagnostic sensitivity. |
The summaries are NHTSA's. Each bulletin's page links NHTSA's copy of the manufacturer's document.