WenmarOpen by Wenmar Pro

Service bulletins for the 2009 Bentley Continental

A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.

138 on file from NHTSA, as of 2026-10-19.

By type

By component

By trouble code

Only bulletins with component: Equipment and accessories are shown. Show all

Bulletins, newest first
2033467/22024-05-07. Service bulletin. EQUIPMENT; VISIBILITY:SUN/MOON ROOF ASSEMBLY; STRUCTURE. Convertible roof - C flap Bowden cable replacement Customer statement / workshop findings: Check convertible roof function. Technical background: Continual improvement in system designs can produce developments that may benefit older vehicles. One such development has been identified in the convertible roof mechanism. Re-route the C flap Bowden cable using a longer cable reduces the friction build up in the system and thus promotes smooth operation of the C flap and longevity in the system.
2069806/52024-04-06. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident.
2043406/32023-12-07. Service bulletin. EQUIPMENT; STRUCTURE. Hood rear bow clash to tonneau cover - prevention (SC16/21). Technical background: Unable to operate convertible roof due to tonneau cover to rear bow clash. The reinforcement plate inside the roof which assists the smooth operation of the system deforms and catches between the frame and the hood. This clash condition if not prevented could also result in damage. to the hood frame tension straps.
2061195/32023-11-07. Service bulletin. EQUIPMENT; ELECTRICAL SYSTEM. Telephone Functionality Complaint - Minimum Standards Required For Analysis Of Concerns. Customer statement / workshop findings: The feedback method within this TPI is required should a complaint of telephone functionality and/or quality be reported. Technical background: The minimum standards check list document within the Measure section is required to capture an accurate description of customer telephone issues.
2058176.42023-11-06. Service bulletin. EQUIPMENT. Sun visor mirror cracked Customer Statement: -Driver or passenger sun visor mirror cracked/broken
2055772.62023-11-06. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT. Battery conditioner inoperative Technical Background: -Corrosion on the contact surfaces of the charger socket and charger lead. If the charging socket or charger lead are wet when the charger is connected this can cause corrosion on the contacts.
2052431.92023-11-06. Service bulletin. EQUIPMENT; ELECTRICAL SYSTEM. New Continental GT and GTC - Rattle / Buzzing Noise - Head-Up display Customer Statement: -Rattle / buzzing noise from Control Unit for Head-Up display - dashboard upper trim panel.
2052092.72023-11-06. Service bulletin. EQUIPMENT ADAPTIVE/MOBILITY; ELECTRICAL SYSTEM; LATCHES/LOCKS/LINKAGES. New Continental GT/C - Door 'soft close' functionality Customer Statement: -Correct functionality and restrictions of the door soft close system need to be understood to prevent unnecessary customer complaints.
2069806/42023-10-06. Service bulletin. EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; STRUCTURE. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Condition HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin. - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident.
2069806/32023-09-07. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. HVAC refrigerant leakage suspected Or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident.
2036678.52023-02-03. Service bulletin. EQUIPMENT; ELECTRICAL SYSTEM. Speaker Replacement - Diagnostic Checks Technical Background: -There have been instances where door speakers have been changed under warranty for the complaint of sound distortion, yet when tested by ourselves and the supplier, no fault could be found with the returned unit.
2051562.92022-11-08. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT. 12 Volt- Battery Condition Checks. Technical background For all 12 volt battery issues relating to warranty or a parts warranty claim, a DISS query MUST be raised prior to battery replacement, refer to the instructions within the Measure section of this TPI.
2063874/22022-10-07. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT. Subwoofer - Part Number 3W7 035404B - No Longer Available (NLA) Customer Statement: -Subwoofer - Part Number (3W7 035 404B) - No Longer Available (NLA) and cannot be sourced or supplied
2061195/12020-12-02. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT. Telephone Functionality Complaint - Minimum Standards Required For Analysis Of Concerns. Customer statement / workshop findings: The feedback method within this TPI is required should a complaint of telephone functionality and/or quality be reported. Technical background: The minimum standards check list document within the Measure section is required to capture an accurate description of customer telephone issues.
2051562/62020-12-02. Service bulletin. EQUIPMENT ADAPTIVE/MOBILITY; EQUIPMENT; ELECTRICAL SYSTEM. All Models - 12 Volt Battery condition checks. Technical background For all 12 volt battery issues relating to warranty or a parts warranty claim, a DISS query MUST be raised prior to battery replacement, refer to the instructions within the Measure section of this TPI.
2058173/22020-11-07. Service bulletin. EQUIPMENT; ELECTRICAL SYSTEM. Electrical switch replacement guidelines. Customer statement/workshop findings: Electrical switch suspected as defective This TPI is not applicable to suspected faulty control units or any component related to the passive restraint system in particular the airbag system Technical background: Prior to replacing an electrical switch refer to the Measure section of this TPI
2042104/12020-01-17. Service bulletin. EQUIPMENT; ELECTRICAL SYSTEM. Telephone Functionality Complaint - Minimum Standards Required For Analysis Of Concerns Customer statement / workshop findings: An improved feedback method is required should a complaint of telephone functionality / quality be reported. Technical background: A minimum standards document is required to capture an accurate description of customer telephone issues. Measure: The attached document should be completed and attached to the relevant DISS query, this will allow a full understanding of the customer complaint and the circumstances in which the complaint becomes apparent.
204340622017-08-25. Service bulletin. EQUIPMENT; STRUCTURE:BODY:HOOD. Hood rear bow clash to tonneau cover - prevention (SC16/21) *Revised: VIN Updates
204340612017-02-09. Service bulletin. STRUCTURE; EQUIPMENT. HOOD REAR BOW CLASH TO TONNEAU COVER – PREVENTION (SC16/21)
204246222017-02-09. Service bulletin. EQUIPMENT; STRUCTURE. HEADLINER REPLACEMENT - RIGHT HAND C POST HEADLINER GUIDE
204340612016-10-04. Service bulletin. EQUIPMENT. HOOD REAR BOW CLASH TO TONNEAU COVER – PREVENTION (SC16/21)
SB-20362667-12016-04-26. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. SUMMARY TO BE PROVIDED ON A FUTURE DATE.
SB-2027658-42016-03-16. Service bulletin. SUSPENSION:FRONT:SHOCK ABSORBER; EQUIPMENT. SUMMARY TO BE PROVIDED ON A FUTURE DATE.
2024809-32016-03-16. Service bulletin. EQUIPMENT; EQUIPMENT:APPLIANCE:AIR CONDITIONER. SUMMARY TO BE PROVIDED ON A FUTURE DATE.
TB-10-01-01-022010-11-20. Service bulletin. EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL; UNKNOWN OR OTHER. BENTLEY: A CONDITION HAS BEEN IDENTIFIED THAT CAN COMPROMISE THE SURFACE FINISH OF THE PIPE SUPPLYING LUBRICANT TO THE TURBOCHARGERS. IF LEFT UNDETECTED THE PIPE MAY CORRODE AND, IN EXTREME CASES, RESULT IN FLUID LOSS. NO MODEL YEARS LISTED. *PE

The summaries are NHTSA's. Each bulletin's page links NHTSA's copy of the manufacturer's document.