Service bulletins for the 2017 Bentley Bentayga
A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.
660 on file from NHTSA, as of 2026-10-19.
By type
By component
By trouble code
Only bulletins with component: Glass, wipers and mirrors are shown. Show all
| 2078373/3 | 2026-08-06. Service bulletin. STRUCTURE:BODY; ELECTRICAL SYSTEM; VISIBILITY/WIPER. Sunroof blind not retracting | Bentayga Series. |
|---|---|
| 2080680/2 | 2026-08-04. Service bulletin. STRUCTURE:BODY; ELECTRICAL SYSTEM; VISIBILITY/WIPER. Organ stop air regulator jammed / broken / electrical value wrong reading. Customer Statement: Airflow from the organ stops (air regulators) is not functioning correctly; vents may be stuck, broken, or showing incorrect operation. |
| 2078190/6 | 2026-06-03. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY/WIPER. AC System not Cooling - HVAC Leakage. Customer Statement: The customer may find that the A/C system not blowing cold air and / or Cooling performance has declined over time. |
| 2057841/4 | 2026-05-07. Service bulletin. STRUCTURE:BODY; VISIBILITY/WIPER. Windscreen replacement criteria whilst under manufacturers warranty. Customer statement / workshop findings: Windscreen cracked/damaged |
| 2077256/4 | 2026-05-05. Service bulletin. ELECTRICAL SYSTEM; STRUCTURE:BODY; VISIBILITY/WIPER. Rear Door Blind Inoperative | Bentayga Series Customer statement / workshop findings: Rear door blind is inoperative |
| 2078190/5 | 2026-04-05. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY/WIPER. AC System not Cooling - HVAC Leakage. Customer Statement: The customer may find that the A/C system not blowing cold air and / or Cooling performance has declined over time. |
| 2078373/2 | 2026-02-04. Service bulletin. STRUCTURE:BODY; VISIBILITY/WIPER; ELECTRICAL SYSTEM. Sunroof blind not retracting | Bentayga Series | 17-26MY. Condition: Customer may report that the sunroof blind is stuck in the closed position and cannot be opened using interior controls. The Sunroof blind is stuck due to uneven/ruffled or crumped during open or closing. |
| 2078190/4 | 2026-01-29. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY/WIPER. AC System not Cooling - HVAC Leakage. Customer Statement: The customer may find that the A/C system not blowing cold air and / or Cooling performance has declined over time. |
| 2078373/1 | 2025-10-07. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY/WIPER; STRUCTURE:BODY. Sunroof blind not retracting | Bentayga Series | 17-26MY. Condition: Customer may report that the sunroof blind is stuck in the open position and cannot be closed using interior controls. The Sunroof blind is stuck due to uneven/ruffled or crumped during open or closing. |
| 2069806/7 | 2025-10-07. Service bulletin. VISIBILITY/WIPER; ELECTRICAL SYSTEM; STRUCTURE:BODY. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines |
| 2077256/3 | 2025-08-29. Service bulletin. VISIBILITY/WIPER; ELECTRICAL SYSTEM; STRUCTURE:BODY. Rear Door Blind Inoperative | Bentayga Series. Condition: Rear door blind is inoperative. |
| 2077256/2 | 2025-07-30. Service bulletin. STRUCTURE:BODY; VISIBILITY/WIPER; ELECTRICAL SYSTEM. Rear Door Blind Inoperative | Bentayga Series |
| 2050542/8 | 2025-07-08. Service bulletin. ELECTRICAL SYSTEM; EXTERIOR LIGHTING; VISIBILITY/WIPER. Front Exterior Lighting Steamed Up/Leaks | 12-24MY. |
| 2069806/6 | 2025-07-08. Service bulletin. VISIBILITY/WIPER; ELECTRICAL SYSTEM. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines. |
| 2078164/1 | 2025-07-08. Service bulletin. VISIBILITY/WIPER; ELECTRICAL SYSTEM. AC System not cooling - HVAC Refrigerant leaks | Bentayga Series | 17 - 25MY. Condition: Customer may report that the air conditioning system is not cooling effectively. |
| 2051519/14 | 2025-05-07. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY/WIPER; STRUCTURE:BODY. HVAC distribution/operational issues - HVAC Motor defect DTC's logged | Continental GT/GTC & Bentayga Series. Condition: • HVAC distribution/operational issues • HVAC motor defect (DTC’s) evident within address 08 - Climatronic control unit, the DTC’s can be static or Intermittent |
| 2061757/3 | 2024-07-06. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY/WIPER. DTC B2000F2: Faulty control module (Symptom code 4102) and/or night vision warning light evident within the (DIP). Customer statement: Night vision warning lamp (Figure 1) is evident with the Drivers Information Panel (DIP). Workshop findings: DTC - B2000F2: Faulty control module (Symptom code 4102) evident within address 0084 - Night vision control module. |
| 2069806/5 | 2024-04-06. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident. |
| 2051519/13 | 2023-12-06. Service bulletin. VISIBILITY; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; ELECTRICAL SYSTEM. HVAC distribution/operational issues - HVAC Motor defect DTCs logged. Customer statement / workshop findings: - HVAC distribution/operational issues - HVAC motor defect (DTCs) evident within address 08 - Climatronic control unit, the DTCs can be static or Intermittent Technical background: Where VIN applicable the operative MUST first conduct Service Campaign EB28 (Bentayga) or EB29 (New Continental GT/GTC). |
| 2060458.3 | 2023-11-08. Service bulletin. VISIBILITY; ELECTRICAL SYSTEM; STRUCTURE. Water Ingress onto the front reading light Customer Statement: -Water drips from the front interior light. The water drips directly from the electric drive of the front sun roof motor. |
| 2050542.7 | 2023-11-06. Service bulletin. ELECTRICAL SYSTEM; EXTERIOR LIGHTING; VISIBILITY. Service info: body/equipment: front exterior lighting steamed up/leaks Customer Statement: -1. The lenses of the headlights (illustration 1a) /front fog lamps (illustration 1b) are steamed up/damp from the inside with minor drips. 2. Water is in the headlight (illustration 2a) / front fog lamp (illustration 2b), big drips. |
| 2069806/4 | 2023-10-06. Service bulletin. EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; STRUCTURE. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Condition HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin. - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident. |
| 2069806/3 | 2023-09-07. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. HVAC refrigerant leakage suspected Or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident. |
| 2069806/2 | 2023-09-07. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; VISIBILITY; ELECTRICAL SYSTEM. HVAC refrigerant leakage suspected Or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident. In the event that HVAC cleaning products are required, these MUST be sourced locally. Before using the cleaner the operative must inform the customer of the product which will be used, a neutral fragrance cleaner should be used as the customer may not like the smell of the cleaner should a fragranced product be used Please ensure all supporting information is included within the DISS query when requesting permission to clean the HVAC system including clear photographs and/or videos showing the reported issue, should the required information not be supplied the warranty claim could be cancelled. |
| 2070682/1 | 2023-08-03. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; ENGINE AND ENGINE COOLING. Loud ticking/clatter noise from the air conditioning compressor (HVAC). Customer statement Loud ticking/clatter noise can be heard from the front of the engine Workshop findings The noise is from the air conditioning compressor Technical background The operative should confirm the noise is from the compressor as detailed within the Measure section. |
The summaries are NHTSA's. Each bulletin's page links NHTSA's copy of the manufacturer's document.