Transport Canada recall 2023029
A recall listed here may apply to a vehicle of this year, make and model. Only the manufacturer can say whether it applies to one vehicle: check the VIN with the official lookups.
| Published by | Transport Canada (Canada) |
|---|---|
| Campaign number | 2023029 |
| Manufacturer's number | RE23/02 (RC67) |
| Reported | 2023-01-27 |
| Component | Heater And Defroster |
| Notification type | Safety Mfr |
| Units potentially affected | 35 |
What is wrong
Issue:
On certain vehicles, water could leak into the external coolant pump for the climate control system and cause a short circuit. If this happens, the pump and wiring could overheat and melt.
Safety Risk:
A short circuit can create the risk of a fire.
Corrective Actions:
Bentley will notify owners by mail and instruct you to bring your vehicle to a dealership to replace the external coolant pump. Additionally, the connections for the pump will be inspected and replaced, if necessary.
| 2020 BENTLEY CONTINENTAL GT | Listed as a series or trim of this model. |
|---|---|
| 2020 BENTLEY CONTINENTAL GTC | Listed as a series or trim of this model. |
A vehicle with no link is not in this site's catalog, which covers cars, multipurpose vehicles and trucks by model year. The campaign is from data as of 2026-10-19.
Bulletins for the same vehicles and component
| 2069806/5 | 2024-04-06. Service bulletin. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident. |
|---|---|
| 2051519/13 | 2023-12-06. Service bulletin. HVAC distribution/operational issues - HVAC Motor defect DTCs logged. Customer statement / workshop findings: - HVAC distribution/operational issues - HVAC motor defect (DTCs) evident within address 08 - Climatronic control unit, the DTCs can be static or Intermittent Technical background: Where VIN applicable the operative MUST first conduct Service Campaign EB28 (Bentayga) or EB29 (New Continental GT/GTC). |
| 2069806/4 | 2023-10-06. Service bulletin. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Condition HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin. - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident. |
| 2069806/3 | 2023-09-07. Service bulletin. HVAC refrigerant leakage suspected Or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident. |
| 2069806/2 | 2023-09-07. Service bulletin. HVAC refrigerant leakage suspected Or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident. In the event that HVAC cleaning products are required, these MUST be sourced locally. Before using the cleaner the operative must inform the customer of the product which will be used, a neutral fragrance cleaner should be used as the customer may not like the smell of the cleaner should a fragranced product be used Please ensure all supporting information is included within the DISS query when requesting permission to clean the HVAC system including clear photographs and/or videos showing the reported issue, should the required information not be supplied the warranty claim could be cancelled. |
| 2070682/1 | 2023-08-03. Service bulletin. Loud ticking/clatter noise from the air conditioning compressor (HVAC). Customer statement Loud ticking/clatter noise can be heard from the front of the engine Workshop findings The noise is from the air conditioning compressor Technical background The operative should confirm the noise is from the compressor as detailed within the Measure section. |
| 2069806.1 | 2023-05-05. Service bulletin. HVAC Refrigerent Leakage - Diagnosis Guidelines Customer Statement: -HVAC not cooling or HVAC cooling less than expected |
| 2051519.11 | 2022-12-08. Service bulletin. HVAC Operation Issues/HVAC Motor defect DTCs logged Customer Statement: -HVAC operation issues and HVAC motor defect (DTCs) evident within address 08 - Climatronic control unit, the DTCs can be static or sporadic (intermittent) |
| 2051519/7 | 2020-11-03. Service bulletin. HVAC operation issues/HVAC Motor defect DTCs logged. Customer statement/workshop findings: HVAC operation issue and HVAC motor defect (DTCs) evident within address 08 Climatronic control unit, the DTCs can be static or sporadic, for example: B108D09: Right temperature flap positioning motor - Component defect Technical background: The HVAC motor/s can become jammed causing HVAC operation issues. |
| 2051519/4 | 2019-10-04. Service bulletin. HVAC operation issues/HVAC Motor defect DTC's logged. The servomotor can become jammed causing HVAC operation issues. |
A bulletin is the manufacturer's note to its dealers. It is not part of this recall.