The bulletins listed name this code in NHTSA's summary, or are about the same components. A bulletin or a recall listed here may apply to the model year. None of it is a diagnosis.
This code is specific to a manufacturer and is not described here. Its meaning is in the manufacturer's service information.
| 08-025-23 | 2023-02-13. Service bulletin. Flash: Hybrid Control Processor (HCP) Updates Customers may experience a Malfunction Indicator Lamp (MIL) illumination. Upon further investigation the technician may find one or more of the following Diagnostic Trouble Codes (DTCs) have been set: P1C64 - Hybrid Perf Engine Speed Below Target During Autostart. U0402 - Implausible Data Received From TCM. Customers may also comment on one or more of the following: During an Engine Stop/Start (ESS) event, the autostart fails and the AutoPark engages. Transmission is in Limp Mode. This bulletin involves updating the HCP with the latest available software. |
|---|---|
| 08-093-22 REV. B | 2023-01-17. Service bulletin. Flash: Hybrid Control Processor (HCP) Updates This bulletin involves updating the HCP with the latest available software. Customers may experience a Malfunction Indicator Lamp (MIL) illumination. Upon further investigation the technician may find one or more ofthe following DTCs have been set: U0402-00 - Implausible Data Received From TCM. P1C64 - Hybrid Perf - Engine Speed Below Target During Autostart. In addition, the following software enhancement is available: Engine Stop/Start (ESS) improvements - Improvements to make ESS more smooth/consistent. Customers may complain of rough or inconsistentautostarts. The customer may also describe one or more of the following: Coast down engine idle improvements (related to two-foot driving below 19kph (12 mph). During an ESS event, the autostart fails and the AutoPark engages. Transmission is in Limp Mode. |
| 08-093-22 | 2022-06-27. Service bulletin. Flash: Hybrid Control Processor (HCP) Updates This bulletin involves updating the HCP with the latest available software. Customers may experience a Malfunction Indicator Lamp (MIL) illumination. Upon further investigation the technician may find one or more ofthe following Diagnostic trouble Codes (DTCs) have been set: P1C64 - Hybrid Perf - Engine Speed Below Target During Autostart. U0402 - Implausible Data Received From TCM. The customer may also describe one or more of the following: During a Engine Stop/Start (ESS) event, the autostart fails and the AutoParkengages. Transmission is in Limp Mode. |
| 9004484 | 2022-06-27. Service bulletin. Motor Generator Unit Engineering is looking to avoid unnecessary part replacements for Motor Generator Unit (MGU) underhood whining noise and P1C64 faults. When replacing the MGU for a bearing noise, connect the scan tool to the vehicle and create a scan report to include with the claim prior to replacement of the MGU. See SOL case S2208000009 for added details. Please check Service Library for available TSBs for your concern. Follow current Service Procedures for each complaint, but call Engineering before removing MGU to gather further information. Contacts: FCA Redacted Content If no response in 15 minutes, proceed with repair. |
4 on file from NHTSA, as of 2026-10-19. See them in the bulletin list. A bulletin lists model years: read the document for which vehicles it concerns.