WenmarOpen by Wenmar Pro

Service bulletins for the 2024 Mercedes-Benz AMG GT

A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.

238 on file from NHTSA, as of 2026-10-19.

By type

By component

By trouble code

By topic

Only bulletins with component: Engine are shown. Show all

Bulletins, newest first
LI15.40-P-0779472024-10-18. Service bulletin. ELECTRICAL SYSTEM; ENGINE. Complaint Combustion engine could no longer be started, only electric driving possible. Cause High-voltage belt-driven starter-alternator faulty. Remedy Requirement: Prior to the implementation of the test work, it must be ensured that the person carrying out this work has successfully completed the required HV qualification to work on HV system.
LI15.40-P-0779472024-09-25. Service bulletin. ENGINE. Complaint Combustion engine could no longer be started, only electric driving possible Cause High-voltage belt-driven starter-alternator faulty Remedy Requirement: Prior to the implementation of the test work, it must be ensured that the person carrying out this work has successfully completed the qualification "T1716F Diagnosis at high voltage level 4" and the vehicle-specific training. Note: In order to check whether the high-voltage belt-driven starter-alternator is faulty, please carry out the test below. If the fault "P0E2F00 The electrical fuse B for the high voltage has a malfunction" is stored in the N82/10 BMS control unit, the HV protocol must be checked to see whether the fuse for the auxiliary consumers is defective. In this case, the high-voltage battery must be replaced after the short circuit has been eliminated. (See attachment) The faulty high-voltage belt-driven starter-alternator must always be sent back via the existing return delivery process for analysis. Check: Please disconnect the high-voltage plug at the high-voltage belt-driven starter-alternator and connect test adapter 000 589 94 63 00. Measure resistance HV+ to HV-. If the final measurement result is between 0–1 ohm, the high-voltage belt-driven starter-alternator with the short circuit must be replaced. If either one of or both the fault codes P0C0B16 and P0C0B17 are saved in the high-voltage belt-driven starter-alternator control unit G2/3, please replace the high-voltage belt-driven starter-alternator, since no short circuit can be measured here and this therefore concerns a hardware defect. Please check the serial number on the silver adhesive label below the SW number on the front of the high-voltage belt-driven starter- alternator. Example: 2314300044 (the first 10 digits, see attachment) Important note: If the number is greater than 2329100027, a TIPS case must be created. In this instance, please attach the following documents to the TIPS case: • Quick test • High-voltage event log • Picture of the silver adhesive label on the front of the high-voltage belt-driven starter-alternator (serial number) • Attach the measurement results with pictures
LI07.70-P-0782932024-08-28. Service bulletin. ENGINE. Complaint Customer states CEL active in instrument cluster Cause Under Investigation Remedy Take no action. Replace no parts. Open a TIPS case and include: • Initial quick test with freeze frame • ME control unit log
LI07.61-P-0707072024-06-01. Service bulletin. ENGINE; FUEL/PROPULSION SYSTEM. The customer complains of a check engine light (CEL) on. May also complain of the engine running roughly and/or a loss of power. Multiple Causes Remedy Please see the document "Remedy Instructions" in attachments. For MY19+ G63 there may be an alternate solution available. Please reference LI07.61-P-076755 before performing the steps in this LI.

The summaries are NHTSA's. Each bulletin's page links NHTSA's copy of the manufacturer's document.