Service bulletins for the 2014 Chevrolet Silverado
A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.
3313 on file from NHTSA, as of 2026-10-19.
By type
By component
By trouble code
By topic
Only bulletins with component: Heating and air conditioning are shown. Show all
| 99-01-39-004E | 2018-05-29. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. This technical bulletin provides a procedure to correct the customers concern of odor coming from the Air conditioning. |
|---|---|
| 99-01-39-004F | 2018-05-29. Service bulletin. EQUIPMENT; EQUIPMENT:APPLIANCE:AIR CONDITIONER; EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL. This technical bulletin provides a procedure to correct the customers concern of odor coming from the Air conditioning. |
| 99-01-39-004G | 2018-05-21. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; ELECTRICAL SYSTEM. This technical bulletin provides repair information for the correction of a customer concern of short duration musty odors emitted from the HVAC system at vehicle start-up in hot, humid conditions. |
| 99-01-39-004F | 2018-05-21. Service bulletin. EQUIPMENT; EQUIPMENT:APPLIANCE:AIR CONDITIONER. This technical bulletin provides a procedure to correct the customers concern of odor coming from the Air conditioning. |
| PI1440 | 2018-05-07. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. This preliminary informational bulletin provides technicians with diagnostic tips for a customer concern of odor emanating from HVAC system. |
| PIT5099A | 2018-05-07. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. This Preliminary Information communication provides information to the technician about vehicles that the Heater-Vent-Air Conditioning blows warm air. Before calling General Motors Technical Assistance Center technician will need to have high and low pressures, outside temperature, humidity, and vent temperature. |
| PIT5331 | 2018-05-07. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. This Preliminary Information communication provides information to the technician about vehicles that the Heater-Vent-Air Conditioning blow warm. Technician will need to replace the compressor to condenser line and install the line bracket. |
| PI1000 | 2018-04-23. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. This preliminary informational bulletin provides information for HVAC ?Sync? Function May Not Retain Selection After Key Cycle Concern. |
| 030848006J | 2017-12-22. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. This informational bulletin provide information for the technicians to repair the rear window defroster contact or tabs. |
| PIT5180A | 2017-12-22. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; EQUIPMENT. This Preliminary Information communication provides information to the technician about vehicle that may have a whistle noise coming from the driver?s side "A" pillar area when driving around 50 mph with the Heater-Vent-Air Conditioning in recirculation mode. Technician will need to reseal the Vehicle Identification Number plate rivets using room temperature vulcanization silicone sealer from the underside. |
| PIT5405A | 2017-08-15. Service bulletin. STEERING; ELECTRICAL SYSTEM; POWER TRAIN; EQUIPMENT:APPLIANCE:AIR CONDITIONER. This Preliminary Information communication provides information to the technician for a reduced power message, steering assist, engine stall or the instrument panel, radio, and or Heater-Vent-Air Conditioning go blank with multiple diagnostic trouble codes. If any of the following diagnostic trouble codes U0073, U0078, U0029, U0028, U0415, U0140, U0126, U0121, U0101, U0100, C0544, U1510, U0073, B127B, B2605, B3600,C0800, U0428, and U0452 set in the vehicle. Check the body control module ground at the G218 location. The front dash insulator mat may be trapped between the ground eyelet and the body stud. Remove the round nut and eyelet and cut the front dash insulator mat away from the ground stud so it no longer interferes with the ground stud and reinstall the eyelet and ground nut. |
| PIT3330G | 2017-08-15. Service bulletin. EQUIPMENT:ELECTRICAL; EQUIPMENT:APPLIANCE:AIR CONDITIONER. This Preliminary Information communication provides information to the technician about customers may inquire about the availability of the passenger compartment air filter. Dealer should advise the customer starting in 2003 the passenger compartment air filter is no longer available as a factory option. For vehicles that are 2007 and later a cabin air filter may be able to be added. Refer to the latest version of PI1216. |
| PIT5343 | 2017-08-15. Service bulletin. ELECTRICAL SYSTEM:SOFTWARE; EQUIPMENT:APPLIANCE:AIR CONDITIONER. This Preliminary Information communication provides information to the technician about when starting the vehicle there is a lack of air flow through the Heater-Vent-Air Conditioning vents and that the indicators on the Heater-Vent-Air Conditioning controls are illuminated and the display may show Heater-Vent-Air Conditioning off. Technician should reprogram the Heater-Vent-Air Conditioning control module using Service Programming System with the latest calibration. |
| PI1440 | 2017-08-15. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. This preliminary informational bulletin provides technicians with diagnostic tips for a customer concern of odor emanating from HVAC system. |
| 06-00-89-026L | 2017-08-15. Service bulletin. SERVICE BRAKES; EQUIPMENT:ELECTRICAL; ENGINE AND ENGINE COOLING:EXHAUST SYSTEM; EQUIPMENT:APPLIANCE:AIR CONDITIONER; POWER TRAIN:AXLE ASSEMBLY; EQUIPMENT ADAPTIVE/MOBILITY; ELECTRICAL SYSTEM. This warranty administration bulletin provide policy information on a revised customer concern not duplicated/verified labor operation numbers and how to submit CCND. |
| PIT5229 | 2017-08-15. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. This Preliminary Information communication provides information to the technician about vehicles that may have excessive dust intruding into the cabin. Technician can update the Heater-Vent-Air Conditioning control module which will close the recirculation door 90% when in recirculation mode. If the customer would like to keep the factory calibration in which the recirculation door closes off 100% of the outside air, please advise the customer to place the Heater-Vent-Air Conditioning system in fresh air mode while traveling on dusty roads. |
| PIT5221 | 2017-08-15. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. This Preliminary Information communication provides information to the technician about vehicles that intermittently after selecting defrost mode they are unable to manually adjust the blower speed lower. Dealer should communicate to the customer this condition is a normal operating characteristic of their vehicle. |
| PIT5240 | 2017-08-15. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; SEATS:FRONT ASSEMBLY:SEAT HEATER/COOLER. This Preliminary Information communication provides information to the technician about customer's questions on what temperature the heated and/or cooled seats will turn on during a remote vehicle start. Dealer should advise the customer that the heated seats will turn on when ambient temperature is below 50 degrees Fahrenheit (10 degrees Celsius) and the cooled seats will turn on when ambient temperature is above 80 degrees Fahrenheit (27 degrees Celsius). |
| PIT5240A | 2017-08-15. Service bulletin. SEATS:FRONT ASSEMBLY:SEAT HEATER/COOLER; EQUIPMENT:APPLIANCE:AIR CONDITIONER. This Preliminary Information communication provides information to the technician about systems operate during a remote vehicle start event. Dual Zone Auto Regular Production Option Code (CJ2) Heater-Vent-Air Conditioning settings the Heater-Vent-Air Conditioning settings will remain set to the previous Heater-Vent-Air Conditioning settings when the ignition was turned off. Single Zone Manual Regular Production Option Code (C67) HVAC settings the Heater-Vent-Air Conditioning settings will remain set to the previous Heater-Vent-Air Conditioning settings when the ignition was turned off. The Rear window defogger during a remote start event, the rear window defogger will turn on if the outside temperature is 44 degrees Fahrenheit (7 degrees Celsius) or below. The heated seats will not turn on if a Remote Vehicle Start event is performed within 2 hours of shutting the engine off. The cooled seats will turn to the high setting when the ambient temperature is above 80 degrees Fahrenheit (27 degrees Celsius). Heated steering wheel will not turn on during Remote Vehicle Start event. |
| PIT5245 | 2017-08-15. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. This Preliminary Information communication provides information to the technician about vehicles that the blower motor may be noisy or vibrate when running. This concern will only occur when the temperatures is below 32 degrees Fahrenheit and if the blower motor is removed while still cold, ice may be found on the blower motor cage. This concern could be caused by water leaking or snow ingestion into the Heater-Vent-Air Conditioning case. Technician is to perform normal water testing diagnostics while the Heater-Vent-Air Conditioning is running, looking for water leaking past the plenum cover. If water is leaking past the cover remove the cover and install a 12x12 snow resistant screen to the fresh air intake. Reseal and install the plenum cover cap using Kent air dry sealer or equivalent. |
| PIT5229A | 2017-08-15. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT:APPLIANCE:AIR CONDITIONER. This Preliminary Information communication provides information to the technician about vehicles that have excessive dust intruding into the cabin. Technician can update the Heater-Vent-Air Conditioning control module with the latest calibration available in TIS2WEB and select the calibration to correct dust intrusion. |
| PIT5245A | 2017-08-15. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; ENGINE AND ENGINE COOLING. This Preliminary Information communication provides information to the technician about vehicles that the blower motor may be noisy or vibrate when running. This concern will only occur when the temperatures is below 32 degrees Fahrenheit and if the blower motor is removed while still cold, ice may be found on the blower motor cage. This concern could be caused by water leaking or snow ingestion into the Heater-Vent-Air Conditioning case. Technician is to perform normal water testing diagnostics while the Heater-Vent-Air Conditioning is running, looking for water leaking past the plenum cover. If water is leaking past the cover remove the cover and install a 12x12 snow resistant screen to the fresh air intake. Reseal and install the plenum cover cap using Kent air dry sealer or equivalent. |
| PIT5240B | 2017-08-15. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT:APPLIANCE:AIR CONDITIONER. This Preliminary Information communication provides information to the technician about systems operate during a remote vehicle start event. Dual Zone Auto Regular Production Option Code (CJ2) Heater-Vent-Air Conditioning settings the Heater-Vent-Air Conditioning settings will remain set to the previous Heater-Vent-Air Conditioning settings when the ignition was turned off. Single Zone Manual Regular Production Option Code (C67) HVAC settings the Heater-Vent-Air Conditioning settings will remain set to the previous Heater-Vent-Air Conditioning settings when the ignition was turned off. The Rear window defogger during a remote start event, the rear window defogger will turn on if the outside temperature is 44 degrees Fahrenheit (7 degrees Celsius) or below. The heated seats will not turn on if a Remote Vehicle Start event is performed within 2 hours of shutting the engine off. The cooled seats will turn to the high setting when the ambient temperature is above 80 degrees Fahrenheit (27 degrees Celsius). Heated steering wheel will not turn on during Remote Vehicle Start event. |
| PIP5179 | 2017-08-15. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; ENGINE. This Preliminary Information communication provides information to the technician about vehicles that have extended or long crank time during cold ambient air temperatures. Direct Injection systems run at higher pressures, and the mechanical pump on the engine must build up the required pressure before the first injection event occurs. Direct Injection engines may have slightly longer cold crank times than that of port fuel engines. |
| PIT5266A | 2017-08-15. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; ELECTRICAL SYSTEM; ELECTRICAL SYSTEM:12V/24V/48V BATTERY. This Preliminary Information communication provides information to the technician about vehicles that during very cold ambient temperatures there may be a no crank or a click no crank condition. Technician will need to check the battery voltage while trying to crank the engine. Replace the battery if it fails the GR8 test. If the battery has more than 11.4 volts while starting and there is a click noise is heard, technician will need to replace the starter and the inspection cover. |
The summaries are NHTSA's. Each bulletin's page links NHTSA's copy of the manufacturer's document.