WenmarOpen by Wenmar Pro

Service bulletins for the 2023 Bentley Flying Spur

A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.

512 on file from NHTSA, as of 2026-10-19.

By type

By component

By trouble code

Only bulletins with component: Glass, wipers and mirrors are shown. Show all

Bulletins, newest first
2051519/122023-10-06. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY; EQUIPMENT. HVAC distribution/operational issues - HVAC Motor defect DTCs logged. Customer statement / workshop findings: - HVAC distribution/operational issues - HVAC motor defect (DTCs) evident within address 08 - Climatronic control unit, the DTCs can be static or Intermittent, NOTE: Before removing any of the following components to gain access to faulty motor(s) the operative MUST raise a technical DISS query to gain permission Hint: A current ODIS log must be attached to the technical DISS query - Dashboard assembly - Head up display unit - HVAC unit.
2069806/42023-10-06. Service bulletin. EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; STRUCTURE. HVAC refrigerant leakage suspected or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Condition HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin. - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident.
2069806/32023-09-07. Service bulletin. ELECTRICAL SYSTEM; EQUIPMENT; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. HVAC refrigerant leakage suspected Or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident.
2069806/22023-09-07. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; VISIBILITY; ELECTRICAL SYSTEM. HVAC refrigerant leakage suspected Or reports of a damp/musty smell within the cabin - Diagnosis guidelines. Customer statement / workshop findings: HVAC not cooling / HVAC cooling less than expected / HVAC refrigerant leakage confirmed Or The customer reports a damp/musty smell within the cabin Note: For this scenario please see the pre requisites below - Should no HVAC leak be evident and a damp/musty smell has been reported/identified the operative should first confirm that water is not leaking into the cabin please refer to all VIN applicable TPIs particularly TPI 2062622/- - Should there be no water leaks evident, the operative should check the HVAC and body drains for blockages, in the event the drains are blocked the drains must be unblocked, once this has been completed the operative should confirm if the damp/musty smell is still evident. In the event that HVAC cleaning products are required, these MUST be sourced locally. Before using the cleaner the operative must inform the customer of the product which will be used, a neutral fragrance cleaner should be used as the customer may not like the smell of the cleaner should a fragranced product be used Please ensure all supporting information is included within the DISS query when requesting permission to clean the HVAC system including clear photographs and/or videos showing the reported issue, should the required information not be supplied the warranty claim could be cancelled.
2070638/12023-08-03. Service bulletin. VISIBILITY; STRUCTURE. Water ingress into the front cabin footwell/bulkhead - Glass misting on the inside - Front carpets/mats wet. Customer statement: - Water ingress into the left and/or right hand foot well - Front carpets and/or foot mats are wet - The windows are misty due to water ingress Workshop findings - After conducting TPI 2062622/- water ingress was found at the location shown in Figure1 (Left hand A - Pillar seam). The cause of the ingress can be caused by missing sealant on the A - post pillar seam.
2070682/12023-08-03. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; ENGINE AND ENGINE COOLING. Loud ticking/clatter noise from the air conditioning compressor (HVAC). Customer statement Loud ticking/clatter noise can be heard from the front of the engine Workshop findings The noise is from the air conditioning compressor Technical background The operative should confirm the noise is from the compressor as detailed within the Measure section.
2070519.12023-07-08. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY:POWER WINDOW DEVICES AND CONTROLS. Window lift switch is loose within the switch carrier and/or a rattle noise can be heard from the switch Customer Statement: -Window lift switch is loose within the door aperture -Or The window lift switch rattles when the door is closed
2069806.12023-05-05. Service bulletin. VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; ELECTRICAL SYSTEM; ENGINE AND ENGINE COOLING. HVAC Refrigerent Leakage - Diagnosis Guidelines Customer Statement: -HVAC not cooling or HVAC cooling less than expected
2066480.52023-04-07. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY. Headlamp Switch Not Working/Not Illuminated - Numerous DTCs within 0009- Central Electrics (BCM1) Customer Statement: -Headlamp switch not working/not illuminated when the ignition is switched on (following and ignition switch off) and/or -Yellow warning light/message within DIP (Adaptive Lighting Fault) and/or -Loss of rear fog light activation and/or -Loss of all-weather lighting mode activation and/or -Headlamps will default to dipped beam
2066480/42023-03-06. Service bulletin. EXTERIOR LIGHTING; VISIBILITY; ENGINE AND ENGINE COOLING; ELECTRICAL SYSTEM. Headlamp Switch Not Working/Illuminated - Numerous DTCs Within 0009 - Central Electrics (BCM1) Customer Statement: -Headlamp switch not working/not illuminated when the ignition is switched on (following an ignition switch off) and/or -Yellow warning light/message within DIP (Adaptive lighting fault) and/or -Loss of rear fog light activation and/or -Loss of all-weather lightin mode activation and/or -Headlamps will default to dipped beam (however, high beam activation will still be possible manually
2051046.62022-12-08. Service bulletin. ELECTRICAL SYSTEM; VISIBILITY. Night vision camera- Washer Jet Leaking Customer Statement: -Washer fluid dripping/leaking from the night vision camera washer jet
2051519.112022-12-08. Service bulletin. VISIBILITY; ELECTRICAL SYSTEM; ENGINE AND ENGINE COOLING; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM. HVAC Operation Issues/HVAC Motor defect DTCs logged Customer Statement: -HVAC operation issues and HVAC motor defect (DTCs) evident within address 08 - Climatronic control unit, the DTCs can be static or sporadic (intermittent)
2066480.32022-12-07. Service bulletin. VISIBILITY; EXTERIOR LIGHTING; ELECTRICAL SYSTEM. Headlamp Switch not working/illuminated - Numerous DTCs within 0009 - Central Electrics (BCM1) Customer Statement: -Headlamp switch not working/not illuminated when the ignition is switched on (following an ignition switch off) and/or -Yellow warning light/message within DIP (Adaptive lighting fault) and/or -Loss of rear fog light activation and/or -Loss of all-weather lighting mode activation and/or -Headlamps will default to dipped beam (however, high beam activation will still be possible manually)
2067489/12022-10-07. Service bulletin. STRUCTURE; VISIBILITY. Window side glass - Identification - Standard (STD) or Privacy (PRV) Customer Statement: - Incorrect side glass fitted - Standard (STD) not Privacy (PRV) or visa versa and/or Defects are evident within the glass Technical Background: -The instructions within the Measure section MUST only be followed if the glass is to be replaced

The summaries are NHTSA's. Each bulletin's page links NHTSA's copy of the manufacturer's document.