WenmarOpen by Wenmar Pro

Service bulletins for the 2005 Audi A8

A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.

245 on file from NHTSA, as of 2026-10-19.

By type

By component

By trouble code

Only bulletins with component: Heating and air conditioning are shown. Show all

Bulletins, newest first
A871569 2020124-2018-02-05. Service bulletin. ELECTRICAL SYSTEM:12V/24V/48V BATTERY; EQUIPMENT:APPLIANCE:AIR CONDITIONER. Supersedes Technical Service Bulletin Group 87 number 14-49 dated April 25, 2014. Air conditioning is inoperative. The HVAC blower functions normally. Battery discharged; however, when charged, there is no bus silence when vehicle ignition is off. The A/C pressure/temperature sensor, G395, leaks refrigerant. This causes sensor G395 to show an incorrect or implausible value when reading MVBs. An incorrect signal or a low refrigerant level in the system can cause the air conditioning compressor to deactivate. The LIN cable connecting the vehicle electrical system control module, J519, to sensor G395 is pinched or cut. This affects the A4/S4, A5/S5 Coupe and Cabriolet, and Q5 vehicles. The A6 and A8 are not affected by this type of failure. The pressure sensor G395/G65 sends an incorrect signal that prevents bus silence and the battery is discharged. Sensor G395 is a LIN slave of the vehicle electrical system control module. The vehicle electrical system control module transfers the information provided by the sensor via the comfort data bus to the climate control module, J255.
A871447 2010146-2017-12-14. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Supersedes Technical Service Bulletin Group 87 number 12-27 dated April 24, 2012. There is an unpleasant, musty odor coming from the heating and ventilation system. The odor usually occurs when the vehicle has been sitting unused for five hours or more. The odor usually occurs within 20 to 60 seconds after the vehicle is started. Condensation, which is a normal condition in all A/C systems, can cause a musty odor. If the odor is noticeable in the vehicle when the engine is not turned on, the cause may be mold and mildew in the passenger compartment, and not be related to the A/C system. All other possible sources of the odor must be investigated before this bulletin can be performed.
A871344 2020124-2017-12-05. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Supersedes Technical Service Bulletin Group 87 number 13-43 dated July 12, 2013. Air conditioning is inoperative. The HVAC blower functions normally. The A/C pressure/temperature sensor, G395, leaks refrigerant. This causes sensor G395 to show an incorrect or implausible value when reading MVBs. An incorrect signal or a low refrigerant level in the system can cause the air conditioning compressor to deactivate. Battery discharged; however, when charged, there is no bus silence when vehicle ignition is off. The LIN cable connecting the vehicle electrical system control module, J519, to sensor G395 is pinched or cut. This affects the A4/S4, A5/S5 Coupe and Cabriolet, and Q5 vehicles. The A6 and A8 are not affected by this type of failure. The pressure sensor G395/G65 sends an incorrect signal that prevents bus silence and the battery is discharged. Sensor G395 is a LIN slave of the vehicle electrical system control module. The vehicle electrical system control module transfers the information provided by the sensor via the comfort data bus to the climate control module, J255.
A871343 2020124-2017-12-05. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Supersedes Technical Service Bulletin Group 87 number 13-42 dated June 11, 2013. Air conditioning is inoperative. The HVAC blower functions normally. Battery discharged; however, when charged, there is no bus silence when vehicle ignition is off. The A/C pressure/temperature sensor, G395, leaks refrigerant. This causes sensor G395 to show an incorrect or implausible value when reading MVBs. An incorrect signal or a low refrigerant level in the system can cause the air conditioning compressor to deactivate. The LIN cable connecting the vehicle electrical system control module, J519, to sensor G395 is pinched or cut. This affects the A4/S4, A5/S5 Coupe and Cabriolet, and Audi Q5 vehicles. The A6 and A8 are not affected by this type of failure. The pressure sensor G395/G65 sends an incorrect signal that prevents bus silence and the battery is discharged. Sensor G395 is a LIN slave of the vehicle electrical system control module. The vehicle electrical system control module transfers the information provided by the sensor via the comfort data bus to the climate control module, J255.
A871342 2020124-2017-11-17. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; ELECTRICAL SYSTEM:12V/24V/48V BATTERY. Supersedes Technical Service Bulletin Group 87 number 12-37 dated November 16, 2012. Air conditioning is inoperative. The HVAC blower functions normally. Battery discharged; however, when charged, there is no bus silence when vehicle ignition is off. The A/C pressure/temperature sensor, G395, leaks refrigerant. This causes sensor G395 to show an incorrect or implausible value when reading MVBs. An incorrect signal or a low refrigerant level in the system can cause the air conditioning compressor to deactivate. The LIN cable connecting the vehicle electrical system control module, J519, to sensor G395 is pinched or cut. This affects the A4/S4, A5/S5 Coupe and Cabriolet, and Audi Q5 vehicles. The A6 and A8 are not affected by this type of failure. The pressure sensor G395/G65 sends an incorrect signal that prevents bus silence and the battery is discharged. Sensor G395 is a LIN slave of the vehicle electrical system control module. The vehicle electrical system control module transfers the information provided by the sensor via the comfort data bus to the climate control module, J255.
A871237 2020124-2017-11-08. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM; ELECTRICAL SYSTEM. Supersedes Technical Service Bulletin Group 87 number 12-32 dated September 5, 2012. Air conditioning is inoperative. The HVAC blower functions normally. Battery discharged; however, when charged, there is no bus silence when vehicle ignition is off. The A/C Pressure/Temperature Sensor G395 leaks refrigerant. This causes Sensor G395 to show an incorrect or implausible value when reading MVBs. An incorrect signal or a low refrigerant level in the system can cause the air conditioning compressor to deactivate. The LIN cable connecting the J519 Central Electrics Control unit to Sensor G395 is pinched or cut. This affects the A4/S4, A5/S5 Coupe and Cabriolet, and Audi Q5 vehicles. The A6 and A8 are not affected by this type of failure. The pressure sensor G395/G65 sends an incorrect signal that prevents bus silence and the battery is discharged. Sensor G395 is a LIN slave of Vehicle Electrical System Control Module J519. Vehicle Electrical System Control Module J519 transfers the information provided by the sensor via the comfort data bus to Climate Control Module J255.
A871449 2020124-2017-11-08. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Supersedes Technical Service Bulletin Group 87 number 13-44 dated August 26, 2013. Air conditioning is inoperative. The HVAC blower functions normally. Battery discharged; however, when charged, there is no bus silence when vehicle ignition is off. The A/C pressure/temperature sensor, G395, leaks refrigerant. This causes sensor G395 to show an incorrect or implausible value when reading MVBs. An incorrect signal or a low refrigerant level in the system can cause the air conditioning compressor to deactivate. The LIN cable connecting the vehicle electrical system control module, J519, to sensor G395 is pinched or cut. This affects the A4/S4, A5/S5 Coupe and Cabriolet, and Q5 vehicles. The A6 and A8 are not affected by this type of failure.The pressure sensor G395/G65 sends an incorrect signal that prevents bus silence and the battery is discharged.
A871563 2010146-2017-10-21. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. Supersedes Technical Service Bulletin Group 87 number 14-54 dated August 28, 2014. There is an unpleasant, musty odor coming from the heating and ventilation system. The odor usually occurs when the vehicle has been sitting unused for five hours or more. The odor usually occurs within 20 to 60 seconds after the vehicle is started. Condensation, which is a normal condition in all A/C systems, can cause a musty odor. If the odor is noticeable in the vehicle when the engine is not turned on, the cause may be mold and mildew in the passenger compartment, and not be related to the A/C system. All other possible sources of the odor must be investigated before this bulletin can be performed.
2020124/82016-05-19. Service bulletin. EQUIPMENT:APPLIANCE:AIR CONDITIONER. SUMMARY TO BE PROVIDED ON A FUTURE DATE.

The summaries are NHTSA's. Each bulletin's page links NHTSA's copy of the manufacturer's document.