Service bulletin FT5271

A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.

The communication, as NHTSA indexes it (as of 2026-10-19)
TypeService bulletin
NHTSA id10213246
Published by NHTSA2022-06-04
Manufacturer's numberFT5271
Manufacturer's date2022-05-17
NHTSA componentEQUIPMENT

NHTSA's summary

Loose drivers stanchion

The document

The document is the manufacturer's. This site does not hold it. NHTSA files a document at one of these two addresses; we have not asked NHTSA which.

Components

Equipment and accessories

Vehicles listed
NOVA BUS LFS2021

Listing a model year does not mean every vehicle of it is concerned: the document says which.

Recalls for the same vehicles and component
24V6570002024-09-09. EQUIPMENT:ELECTRICAL; VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM:WINDSHIELD:ELECTRICAL HEATING ELEMENT
23V7630002023-11-11. EQUIPMENT:APPLIANCE:AIR CONDITIONER

A recall listed here may apply to some of the same vehicles. Only the manufacturer can say whether it applies to one vehicle.

Other bulletins for the same vehicles and component
FT53852023-04-03. Service bulletin. American seating lower bracket hardware missing. Seating lower bracket hardware is missing due to insufficient torque and sealant.
FT53912023-04-03. Service bulletin. American seating lower bracket hardware missing. Seating lower bracket hardware is missing due to insufficient torque and sealant.
FT53862023-04-03. Service bulletin. Loose fuel tank due to improperly torqued hardware and missing hardware.
BS5356E2023-04-03. Service bulletin. Lexan panels cracking at mounting holes. Need to change the attachment of Lexan panels due to apparent cracks.
FT53482023-02-24. Service bulletin. Wheelchair ramp deploy switch hardware loose.
LI5315E2022-10-27. Service bulletin. On the Thermo King HVAC roof unit, after replacing the actuator N8897109, some customers could see the error code 36.
BS5301E2022-10-03. Service bulletin. HVAC deflectors are breaking at the folded attachment points. The brackets broke right at the bending due to a sharp curve
BS5300E2022-10-03. Service bulletin. HVAC deflectors are breaking at the folded attachment points. The brackets broke right at the bending due to a sharp curve
FT5260R12022-08-31. Service bulletin. Need to change the attachment of Lexan panels due to apparent cracks observed in production.
FT5271R12022-06-04. Service bulletin. Loose drivers stanchion