Service bulletin SSM71940
A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.
| Type | Service bulletin |
|---|---|
| NHTSA id | 10206629 |
| Published by NHTSA | 2022-01-18 |
| Manufacturer's number | SSM71940 |
| Manufacturer's date | 2014-08-11 |
| NHTSA component | VISIBILITY:DEFROSTER/DEFOGGER/HVAC SYSTEM |
NHTSA's summary
L405 Range Rover/L494 Sport HVAC Odour Post Assured Vin Reports - L405 Range Rover or L494 Range Rover Sport Customer may report a HVAC odour can be detected post the assured vin's listed in the TSB LTB00590v6 (Or where this has already being carried out) Assured Vin's = Range Rover Skport 140400, 321100.
The document
The document is the manufacturer's. This site does not hold it. NHTSA files a document at one of these two addresses; we have not asked NHTSA which.
Components
Glass, wipers and mirrors, Heating and air conditioning
| LAND ROVER RANGE ROVER | 2014 |
|---|
Listing a model year does not mean every vehicle of it is concerned: the document says which.
| SFCC_SEP2024_52 | 2024-10-07. Other. A customer may report that the windshield wipers stop up on the windshield when turned off. |
|---|---|
| SSM69318 | 2022-01-18. Service bulletin. Air Conditioning compressors premature failure due to incorrect run in procedure |
| LTB00602NAS1 | 2021-12-13. Service bulletin. Technical Bulletin: Sun Visor Vanity Mirror Sliding Cover Open/Closes While Driving |
| SSM72106 | 2021-11-08. Service bulletin. Range Rover/Sport (L405/494) Side Window Intialisation - Range Rover/Sport (L405/L494) Customer may report that either Front or Rear Side windows are not either closing fully or not going fully down when opening. Customers may report a hard Close is not occurring upon operation. |
| LTB00693NAS3 | 2021-03-15. Service bulletin. One or more of the following Air Conditioning (A/C) system symptoms may be evident: ? Vent temperatures 'cycle' (blowing warm and then cold); ? Windshield, rear window, and/or door windows mist up in cool (15°C or lower) ambient temperatures; ? Poor cooling performance of the Air Conditioning (A/C) system; and/or ? Warm, damp or musty smells coming from the vents. |
| LTB00891NAS3 | 2020-11-06. Service bulletin. The roof opening panel rear glass seal may be loose / adrift. |
| SSM74668 | 2020-01-07. Service bulletin. A customer may report warm air instead of cool air from the air distribution and face vents when the air conditioning system is in operation and low temperature selected. |
| SFCC AUG19 Slide | 2019-09-23. Service bulletin. A customer may report that the roof blind does not open smoothly or binds up / jams while operating. |
| LTB00794NAS4 | 2018-11-26. Service bulletin. A chemical/plastic odor from the Heating Ventilation and Air Conditioning (HVAC) system may be evident. |
| LTB01060NAS2 | 2018-10-29. Service bulletin. One or more power windows may be inoperative. |