{"nhtsa_id":10091452,"type":"service_bulletin","type_name":"Service bulletin","date_added":"2017-02-13","date":"2016-08-19","document_id":"ITB16-033","mfr_campaign":null,"replaces":null,"component":"ELECTRICAL SYSTEM:12V/24V/48V BATTERY","mfr_system":null,"summary":"\"2017 QX30; MAIN 12 VOLT BATTERY TESTING WITH MIDTRONICS GR8 OR EXP800 SERVICE INFORMATION WHEN TESTING THE MAIN 12V BATTERY OF AN APPLIED VEHICLE WITH THE MIDTRONICS GR8 OR EXP800, FOLLOW THE DIRECTIONS IN THIS BULLETIN ON PAGES 1 AND 2: - THE MIDTRONICS GR8 OR EXP800 TEST LEADS MUST BE CONNECTED DIRECTLY TO THE POSTS ON THE MAIN 12V BATTERY AS SHOWN IN FIGURE 1 (NOT THE REMOTE TERMINAL CHECK POINTS) TO AVOID INCORRECT CCA MEASUREMENTS. NOTE: THE REMOTE TERMINAL CHECK POINTS CAN BE USED FOR ALL OTHER BATTERY CHARGING OR VOLTAGE CHECKING PROCEDURES, BUT WILL GIVE INACCURATE CCA MEASUREMENTS DUE TO VOLTAGE DROPS BETWEEN THEM AND THE MAIN 12V BATTERY.\"","document":null,"url":"https://open.wenmarpro.com/bulletins/10091452","components":[{"id":"electrical","name":"Electrical system","parent":null},{"id":"battery","name":"12-volt battery","parent":"electrical"}],"codes":[],"topics":[],"vehicles":[{"make":"INFINITI","model":"QX30","year_from":2017,"year_to":2017,"match":"exact","vehicle_ids":["2017_infiniti_qx30"]}],"as_of":"2026-10-19","note":"A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.","attribution":[]}