# Wire gauge calculator for 12 V and 24 V

Works out the voltage drop of each wire gauge for a current and a length at 12 V or 24 V, and names the thinnest wire that stays within the drop allowed. This page describes the calculator and does not compute. The calculator is a web page with a form.

## What you enter

The system voltage, 12 V or 24 V; the current in amperes; the length of wire the current flows through, in metres or feet; and the voltage drop allowed, as a percent.

Left empty, the voltage drop allowed is 3%. That is an example to start from, not a standard: use the figure the equipment's maker gives.

This is voltage drop only. A wire must also carry the current without overheating, which depends on its insulation, on how it is bundled and on the heat around it, and the circuit needs a fuse sized for the wire. Check the wire maker's rating. The length is every metre the current flows through: where a second wire brings the current back, count both.


## How this is worked out

Voltage drop = current × resistance of the wire per metre × length of wire.

Percent = voltage drop ÷ system voltage, which is taken as 12 V or 24 V.

A wire is within the drop allowed when its percent is no more than the percent allowed. One foot is 0.3048 metres.

The resistance of each gauge is read from the sources listed. Each drop is rounded once, to a thousandth of a volt, and its percent is worked from the drop as shown.


## The wire table

Not yet checked. The resistance of each gauge has not been read from a published source yet, so nothing is worked out.

The resistance of each gauge has not been read from a published source yet.


## Use it

The calculator as a web page:

- [Wire gauge calculator for 12 V and 24 V](https://open.wenmarpro.com/tools/wire-gauge)