NHTSA recall 92V147000
A recall listed here may apply to a vehicle of this year, make and model. Only the manufacturer can say whether it applies to one vehicle: check the VIN with the official lookups.
| Published by | NHTSA (United States) |
|---|---|
| Campaign number | 92V147000 |
| Manufacturer | CHRYSLER CORPORATION |
| Reported | 1992-10-14 |
| Owners notified | 1993-03-25 |
| Component | FUEL SYSTEM, GASOLINE |
| Units potentially affected | 3000 |
What is wrong
FUEL TANK FLANGES WERE NOT BENT AS REQUIRED TO ALLOW THE SPECIFIED CLEARANCE FOR THE FUEL TANK MOUNTING STRAPS AND FUEL LINES AT THE TANK.
What can happen
THE UNBENT FLANGES TO THE FUEL TANK WILL DAMAGE THEMOUNTING STRAPS AND/OR FUEL LINES. THE DAMAGED MOUNTING STRAPS MAY BREAK CAUSINGTHE TANK TO DROP AND THE DAMAGED FUEL LINE WILL LEAK FUEL. IN EITHER CASE A FIRECOULD RESULT IF THE SPILLED FUEL IS EXPOSED TO AN IGNITION SOURCE.
The remedy
REPAIR THE FLANGE BY BENDING TO THE CORRECT ANGLE; REPLACE DAMAGED FUEL LINES AND MOUNTING STRAPS.
Notes
SYSTEM: FUEL TANK.VEHICLE DESCRIPTION: PASSENGER VANS.
| 1992 CHRYSLER TOWN AND COUNTRY | Built 1992-04-01 to 1992-04-01. |
|---|---|
| 1992 DODGE CARAVAN | Built 1992-04-01 to 1992-04-01. |
| 1992 PLYMOUTH VOYAGER | Built 1992-04-01 to 1992-04-01. |
A vehicle with no link is not in this site's catalog, which covers cars, multipurpose vehicles and trucks by model year. The campaign is from data as of 2026-10-19.