# P2136 on the 2020 Mercedes\-Benz AMG GT

The bulletins listed name this code in NHTSA's summary, or are about the same components. A bulletin or a recall listed here may apply to the model year. None of it is a diagnosis.

Nobody has written a description of this code yet.

## Bulletins for this model year that name P2136

- [11036076](https://open.wenmarpro.com/bulletins/11036076), 2026-08-10: Complaint Customer reports Check Engine Light with possible loss of power concern. The Following DTC's are present • P210185 \- The throttle valve actuator has a malfunction. There is a signal above the permissible limit value. • P213500 \- The values from the position sensors of the throttle valve are implausible relative to each other • P213600 \- The values from position sensors "A/C" of the throttle valve are implausible relative to each other • P210B85 \- The throttle valve actuator 2 has a malfunction. There is a signal above the permissible limit value. • P2AD300 \- The values from the position sensors "A/G" of the throttle valve are implausible relative to each other • P2AD200 \- The values from position sensors "B/G" of the throttle valve are implausible relative to each other. Cause Increased electrical resistance in pins for left and right throttle actuators. \(M16/60 and M16/61\) Remedy Replaced left and right throttle actuator Sockets with updated part. Silver Coated Pins 8x A 003 982 70 26 \(according to wiring diagram 0,5mm\) Gold Coated Pins 4x A 003 982 75 26 \(according to wiring diagram 0,75mm\) ELA Seals 12x A 001 545 50 80
- [11032873](https://open.wenmarpro.com/bulletins/11032873), 2026-05-20: Complaint Customer reports Check Engine Light with possible loss of power concern. The Following DTC's are present • P210185 \- The throttle valve actuator has a malfunction. There is a signal above the permissible limit value. • P213500 \- The values from the position sensors of the throttle valve are implausible relative to each other • P213600 \- The values from position sensors "A/C" of the throttle valve are implausible relative to each other • P210B85 \- The throttle valve actuator 2 has a malfunction. There is a signal above the permissible limit value. • P2AD300 \- The values from the position sensors "A/G" of the throttle valve are implausible relative to each other Cause Increased electrical resistance in pins for left and right throttle actuators. \(M16/60 and M16/61\) Remedy Replaced left and right throttle actuator Sockets with updated part. Silver Coated Pins 8x A 003 982 70 26 \(according to wiring diagram 0,5mm\) Gold Coated Pins 4x A 003 982 75 26 \(according to wiring diagram 0,75mm\) ELA Seals 12x A 001 545 50 80
- [11031698](https://open.wenmarpro.com/bulletins/11031698), 2026-04-29: Complaint Customer reports Check Engine Light with possible loss of power concern. The Following DTC's are present • P210185 \- The throttle valve actuator has a malfunction. There is a signal above the permissible limit value. • P213500 \- The values from the position sensors of the throttle valve are implausible relative to each other • P213600 \- The values from position sensors "A/C" of the throttle valve are implausible relative to each other Cause Increased electrical resistance in pins for left and right throttle actuators. \(M16/60 and M16/61\) Remedy Replaced left and right throttle actuator Sockets with updated part. Silver Coated Pins 8x A 003 982 70 26 \(according to wiring diagram 0,5mm\) 4x A 003 982 75 26 \(according to wiring diagram 0,75mm\) ELA Seals 12x A 001 545 50 80
