Service bulletin TSB220259

A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.

The communication, as NHTSA indexes it (as of 2026-10-19)
TypeService bulletin
NHTSA id10233018
Published by NHTSA2023-03-20
Manufacturer's numberTSB220259
Manufacturer's date2023-02-03
NHTSA componentELECTRICAL SYSTEM

NHTSA's summary

This Technical Service Bulletin describes the verification and resolution of the HMI320 screen displaying start up message'establishing communication', Fault Code FS1689 - reset Real Time Clock and Fault Code FC 2895 - PCC Net device failed. The communication issue was due to internal failure of Super capacitor C216 in PCC board 3300. Faulty PCC boards 3300 were replaced with good ones. This is an update to a previously submitted communication.

The document

The document is the manufacturer's. This site does not hold it. NHTSA files a document at one of these two addresses; we have not asked NHTSA which.

Components

Electrical system

Vehicles listed
CUMMINS CUMMINS

Listing a model year does not mean every vehicle of it is concerned: the document says which.