A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.
| Type | Service bulletin |
|---|---|
| NHTSA id | 10200430 |
| Published by NHTSA | 2021-08-18 |
| Manufacturer's number | SIL 820 |
| Manufacturer's date | 2021-08-16 |
| NHTSA component | EQUIPMENT ADAPTIVE/MOBILITY; EQUIPMENT; STRUCTURE |
NHTSA's summary
Some customers have reported a crack in the side plate of the mounting frame on some AT200A aerial devices built on Ford F450/F550 chassis from 2011 to 2016 with non-steel utility bodies. Altec requires that each unit be inspected for cracking in the mounting frame side plate no later than the next periodic maintenance interval. Altec requires the kit to be installed within one year of the inspection if the side plate has no cracking or within 90 days of the inspection if the side plate is partially cracked. If the side plate is fully cracked, the unit must be taken out of service until the kit is installed. The inspection and repair are covered under the Altec Warranty Policy and can be performed by Altec, the customer, or the customer’s warranty provider. All welds must be applied by a welder having the AWS D1.1 3G qualification for steel. An Altec Mobile Service technician can perform this inspection but is not able to perform this repair. Altec will perform the repair for free at an Altec facility.
The document
The document is the manufacturer's. This site does not hold it. NHTSA files a document at one of these two addresses; we have not asked NHTSA which.
Components
Body and frame, Equipment and accessories
| ALTEC AT200A | 2011 to 2013 |
|---|---|
| ALTEC AT200A | 2016 |
Listing a model year does not mean every vehicle of it is concerned: the document says which.