Service bulletin ITB20-027
A bulletin is a manufacturer's communication to its dealers, as NHTSA indexes it. The summary is NHTSA's. The document is the manufacturer's: read it at NHTSA. A bulletin is not a recall, and listing a model year does not mean every vehicle of it is concerned.
| Type | Service bulletin |
|---|---|
| NHTSA id | 10185379 |
| Published by NHTSA | 2021-01-09 |
| Manufacturer's number | ITB20-027 |
| Manufacturer's date | 2020-12-01 |
| NHTSA component | ELECTRICAL SYSTEM; POWER TRAIN:AUTOMATIC TRANSMISSION:CONTROL MODULE (TCM/PCM/TECM) |
NHTSA's summary
PERMANENT DTC SET IN TCM AND WILL NOT ERASE IF YOU CONFIRM One or more of the following DTCs are stored in the permanent DTC screen (Figure 1): P0715, P0716, P0718, P0730, P0791, P0793, P0794, P1722, P1742, P1745, P17F0, P17F1, P2766 And The DTCs will not erase when following the ESM procedure. NOTE: • If DTCs other than those listed above are stored, this bulletin does not apply. ACTION Replace the TCM.
The document
The document is the manufacturer's. This site does not hold it. NHTSA files a document at one of these two addresses; we have not asked NHTSA which.
Components
Electrical system, Transmission and driveline, Automatic transmission, Transmission control module
Trouble codes named
P0715, P0716, P0718, P0730, P0791, P0793, P0794, P1722, P1742, P1745, P17F0, P17F1, P2766
| INFINITI QX50 | 2019 |
|---|
Listing a model year does not mean every vehicle of it is concerned: the document says which.
| ITB18-028 | 2018-09-17. Service bulletin. 2019 QX50; MIL ON WITH DTC P0606 IF YOU CONFIRM The MIL is ON with DTC P0606 (CONTROL MODULE [control module processor]) stored. ACTION 1. Refer to step 6 in the SERVICE PROCEDURE to confirm this bulletin applies to the vehicle you are working on. 2. If this bulletin applies, reprogram the ECM. |
|---|---|
| ITB13-035c | 2018-09-17. Service bulletin. CVT FLUID LEVEL CHECK SERVICE INFORMATION This bulletin has been amended. The APPLIED VEHICLES and SERVICE INFORMATION sections have been revised. No other changes have been made. Please discard all previous versions of this bulletin. |