## NHTSA's summary

SB\-16\-020 An enhanced fuel cut valve is available to address a potential sticking condition that results in excess residual pressure in the dosing injector \(7thinjector\) supply pipe. A sticking fuel cut valve may result in the following DTC?s \(diagnostic trouble codes\) setting: 1. If DTC P0005 \(fuel cut valve stuck closed\) sets in the engine ECU, replace the fuel cut valve with the part number listed below. 2. If DTC P20DE \(pressure sensor performance invalid\) or DTC P20DF \(pressure sensor signal too low\) set in the engine ECU, this could be a result of the fuel cut valve sticking. Follow the workshop manual diagnostic procedure in section 4 of the Hino Workshop Manual \(J05E Engine Control System\) for the DTC. Also, inspect for signs of fuel contamination that could restrict the fuel filter or bubble separator filter. If no issues are identified with fuel contamination, and the workshop manual procedure does not identify a concern, replace the fuel cut valve with the part number listed below.

## The document

- [NHTSA's copy of the document (PDF)](https://static.nhtsa.gov/odi/tsbs/2016/MC-10117751-9999.pdf)
- [If that address does not open, try this one](https://static.nhtsa.gov/odi/tsbs/2016/MC-10117751-0001.pdf)

The document is the manufacturer's. This site does not hold it.

## Components

Engine, Fuel system

## Trouble codes named

P0005, P20DE, P20DF

## Vehicles listed

- 2013 HINO JHD2
- 2013 to 2017 HINO JHP2